— 6 —
KV-20S90 / 21SE43C
Detected Symptoms
SELF-DIAGNOSTIC FUNCTION
*If a +B overcurrent is detected, stoppage of the vertical defl ection is detected simultaneously. The symptom that is diagnosed fi rst by the
mircrocontroller is displayed on the screen.
**Refer to Screen (G2) Adjustments in Section 2-4. of this manual.
Display of Standby/Timer LED Flash Count
2 times
4 times
5 times
LED ON 0.3 sec.
LED OFF 0.3 sec.
LED OFF
3 sec.
Diagnostic Item
Flash Count*
+B Overcurrent
2 times
Vertical Defl ection Stopped 4 times
White Balance Failure
5 times
*One fl ash count is not used for self-diagnostic.
Stopping the Standby/Timer LED Flash
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY/TIMER LAMP from fl ashing.
Self Diagnosis
Supported model
Standby/Timer LED
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER LED will automatically begin to fl ash. The number
of times the LED fl ashes translates to a probable source of the problem. A defi nition of the STANDBY/TIMER LED fl ash indicators is listed in the
instruction manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review
the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
Diagnostic Test Indicators
When an error occurs, the STANDBY/TIMER LED will fl ash a set number of times to indicate the possible cause of the problem. If there is more than
one error, the LED will identify the fi rst of the problem areas.
Results for all of the following diagnostic items are displayed on screen. No error has occurred if the screen displays a “0”.
Power does not turn on
+B overcurrent (OCP)*
Vertical Defl ection
Stopped
White Balance failure
(not balanced)
Does not light
2 times
4 times
5 times
2:0 or 2:1
4:0 or 4:1
5:0 or 5:1
• Power cord is not plugged in.
• Fuse is burned out (F601). (A Board)
• H.OUT (Q502) is shorted.(A Board)
• IC1751 (C Board) is shorted.
• +13V is not supplied. (A Board)
• IC541 is faulty. (A Board)
• Video OUT (Q392 to Q394) is faulty.
(A Board)
• IC301 is faulty. (A Board)
• Screen (G2) is improperly
No. of times
STANDBY/ TIMER
lamp fl ashes
Diagnostic Item
Description
Self-Diagnositc
Display/
Diagnostic Result
Probable Cause Location
• Power does not come on.
• No power is supplied to the TV.
• AC Power supply is faulty.
• Power does not come on.
• Load on power line is shorted.
• Has entered standby state after horizontal raster.
• Vertical defl ection pulse is stopped.
• Power line is shorted or power supply is stopped.
• No raster is generated.
• CRT Cathode current detection reference pulse
output is small.
Содержание TRINITRON KV-20S90
Страница 44: ...4 081 454 21 KV 13M42 KV 20M42 KV 20S90 2001 by Sony Corporation Trinitron Color TV Operating Instructions ...
Страница 45: ......
Страница 53: ...Connecting Additional Equipment ...
Страница 55: ...User Guide ...
Страница 63: ......
Страница 79: ......
Страница 83: ......
Страница 86: ......
Страница 87: ......
Страница 88: ......
Страница 89: ......
Страница 90: ......
Страница 91: ...Sony Corporation Printed in U S A ...