5-1. CIRCUIT BOARDS LOCATION
C Board
V Board
GS Board
HS Board
MD Board
A Board
DMB Assembly
been carefully factory-selected for each set in order to satisfy regulations
regarding X-ray radiation. Should replacement be necessary, replace only
with the value originally used.
When replacing components identifi ed by
Y
, make the necessary
adjustments as indicated. If the results do not meet the specifi ed value,
change the component identifi ed by
X
and repeat the adjustment until
the specifi ed value is achieved.
(Refer to Section 3: Safety Related Adjustments on Page 27.)
When replacing the parts listed in the table below, it is important to
perform the related adjustments.
C531, C532, D519, D520,
D521, IC501, IC600, PH602,
R529, R530, R531, R532,
R533, R550, T503 (FBT),
T504 (DFT)
HV HOLD-DOWN
R530, R531
Part Replaced (
Y
)
Adjustment (
X
)
SECTION 5: DIAGRAMS
5-2. PRINTED WIRING BOARD AND
SCHEMATIC DIAGRAM INFORMATION
All capacitors are in µF unless otherwise noted. pF : µµF 50WV or less
are not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise specifi ed.
All resistors are in ohms. k=1000, M=1000k
Indication of resistance, which does not have one for rating electrical
power, is as follows: Pitch : 5mm Rating electrical power :
1
/
4
W in resistance,
1
/
10
W and
1
/
8
W in chip resistance.
: nonfl ammable resistor.
: fusible resistor.
: internal component.
: panel designation and adjustment for repair.
: earth ground
: earth-chassis
All variable and adjustable resistors have characteristic curve B, unless
otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10M digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production tolerances.
All voltages are in V.
S : Measurement impossibillity.
: B+line.
: B-line.
(Actual measured value may be different).
: signal path. (RF)
Circled numbers are waveform references.
The components identifi ed by
X
in this basic schematic diagram have
REFERENCE INFORMATION
RESISTOR
: RN
METAL FILM
: RC
SOLID
: FPRD NONFLAMMABLE CARBON
: FUSE NONFLAMMABLE FUSIBLE
: RW
NONFLAMMABLE WIREWOUND
: RS
NONFLAMMABLE METAL OXIDE
: RB
NONFLAMMABLE CEMENT
: ADJUSTMENT
RESISTOR
COIL
: LF-8L MICRO INDUCTOR
CAPACITOR
: TA
TANTALUM
: PS
STYROL
: PP
POLYPROPYLENE
: PT
MYLAR
: MPS
METALIZED POLYESTER
: MPP
METALIZED POLYPROPYLENE
: ALB
BIPOLAR
: ALT
HIGH TEMPERATURE
: ALR
HIGH RIPPLE
The components identifi ed by shading and
!
symbol are critical for
safety. Replace only with part number specifi ed.
The symbol
indicates a fast operating fuse and is displayed on
the component side of the board. Replace only with fuse of the same
rating as marked.
Les composants identifi es per un trame et une marque
!
sont critiques
pour la securite. Ne les remplacer que par une piece portant le numero
specifi e.
Le symbole
indique une fusible a action rapide. Doit etre remplace
par une fusible de meme yaleur, comme maque.