CPD-420GS/GST
—12—
2-1. CABINET REMOVAL
2-2. SERVICE POSITION
2-3. D, H, N and A BOARD REMOVAL
Cabinet
1
3
2
Two screws
(BVTP 4 x 16)
Two claws
PUSH
PUSH
1
2
3
A board
H board
(additional board)
D board
rotate 180º
Cable bracket
Two Cable stoppers
Five screws
(BVTP 3 x 12)
D board
One screw
(BVTT 4 x 8)
1
4
5
7
3
8
Holder
10
A board
Two screws
(BVTP 3 x 12)
6
N board
2
H board
9
SECTION 2
DISASSEMBLY
1 When the D-board is
placed in service
position, the Safety Earth
Wire (green and yellow
wire) is disconnected.
2 After service is
completed and the
D-board reinstalled, the
Safety Earth Wire must
be reattached to the
chassis with the proper
screw. This must be
confirmed before any
subsequent procedures
are attempted.