TCM-400DV
5
SECTION 3
MECHANICAL ADJUSTMENTS
Tape Tension Measurement
1. Clean the following parts with a denatured-alcohol-moistened
pinch roller
rubber belt
2. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head demagnetizer close to the erase
head.)
parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage (2.5 V) unless otherwise noted.
Mode
Torque Meter
Meter Reading
1.97 – 3.92mN•m
FWD
(20 – 40 g•cm)
CQ-102C
(0.28 – 0.55 oz•inch)
0.05 – 0.49 mN•m
Forward Back
(0.5– 5 g•cm)
Tension
(0.007 – 0.069 oz•inch)
FF, REW
CQ-201B
more than 4.91 mN•m
(more than 50 g•cm)
(more than 0.69 oz•inch)
Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 50 g
(more than 1.76 oz)
2-4. BELT (CAP), BELT (PULLEY), M901 (CAPSTAN/REEL MOTOR),
HRP901 (REC/PB HEAD), HE901 (ERASE HEAD)
HRP901
(REC/PB head)
Attaching belt (CAP)
and belt (pulley)
z
Belt (CAP)
Belt (CAP)
Belt (pulley)
Belt (pulley)
Screws (M1.4)
3
M901
(Capstan/reel
motor)
4
1
8
7
Fly ASSY,
capstan
Washer
6
Washer
5
0
qs
9
2
Washer
(stopper N)
Screws
HE901
(Erase head)
qa
Screw
Torque Measurement