14

Setting Up the System

System Connection

This section explains how to connect the system.

Chairman’s unit/delegate’s unit and
interpreter’s unit

The SX-M100 Control Unit is provided with four
DELEGATE’S/CHAIRMAN’S UNIT connectors.
Up to 15 chairman’s/delegate’s units can be
connected to each of the DELEGATE’S/
CHAIRMAN’S UNIT connectors in serial
connection. The distance between the control unit
and the last chairman’s/delegate’s unit should not
exceed 60 meters (196.8 feet).

Notes

• Be sure to turn off the power of any units before

attempting connection or disconnection.

• The desktop type SX-C100A/D100A and the

desk-mounted SX-C150/D150 are used with this
system.
It is not recommended to mix both combinations.

• When the SX-C100A/D100A is used, the SX-

C700A/C750/D700A/D750 Chairman’s Unit/
Delegate’s Unit, designed for the simultaneous
interpretation conference system, can be
connected to configure this conference system.
However,  after the system power is turned on,
the microphone indicator and MIC ON/OFF
buttons of the chairman’s unit and delegate’s unit
continue to blink for about 3 seconds to inform
that the SX-C700A/D700A units for
simultaneous interpretation conference system
have been connected to the conference system.

• If you turn on the system power before

connecting the chairman’s unit/delegate’s unit,
the microphone indicators and MIC ON/OFF
buttons continue to blink and these units cannot
be controlled by the control unit. In such a case,
turn the power off, then back on again.

• When using the DELEGATE’S/CHAIRMAN’S

UNIT connectors of the SX-M100 Control Unit,
attach the dust caps removed from the 20-pin
multi-connectors on the control unit to the 20-pin
multi-connectors on the last unit connected.
If the 20-pin multi-connector has no dust cap,
keep it away from metal tools, such as
screwdrivers to prevent the connector being
inadvertently shorted.

Precautions

Safety precautions

Power supply

• Operate the unit only with a power source as

specified in “Specifications” section.

• Do not drop or place heavy objects on the power

cord. If the power cord is damaged, turn off the
power immediately. It is dangerous to use the
unit with a damaged power cord.

• Disconnect the power cord from the AC outlet by

grasping the plug, not by pulling the cord.

Keep foreign objects out of the cabinet

Dropping flammable or metal objects into the
cabinet, or spilling liquids onto the cabinet can
lead to accidents.

In case of malfunctions

If you notice any unusual sound, smell or smoke,
turn off the power immediately, disconnect the
power supply and contact your Sony dealer.

Cleaning

Clean the cabinet and panels by wiping with a soft,
dry cloth. For severe stains, moisten the cloth with
a small amount of neutral solvent, and finish by
wiping with a dry cloth. Do not use alcohol,
benzine, thinner or volatile liquids, as these may
discolor or damage the cabinet surface.

Содержание SX-C100A

Страница 1: ...nce System Model SX M100 SX C100A SX C150 SX D100A SX D150 SX T100 Control Unit Telephone Coupler Operating Instructions Before operating the unit please read this manual thoroughly and retain it for future reference Chairman s Unit Delegate s Unit ...

Страница 2: ... correct the interference at his own expense You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment The shielded interface cable recommended in this manual must be used with this equipment in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules For the customers in C...

Страница 3: ...gate s Unit 9 SX T100 Telephone Coupler 13 Setting Up the System 14 Precautions 14 System Connection 14 Turning On the Power of the System 16 Preparing the Control Unit 17 Operation During a Conference 19 Operation Performed by the Chairman and Delegates 19 Taking Part in a Conference via a Telephone 20 Troubleshooting Guide 21 Specifications 22 Table of Contents ...

Страница 4: ...sks These units feature both a microphone and speaker Use the above combination of the chairman s unit and delegate s unit SX T100 Telephone Coupler This coupler is used to connect the control unit to a telephone line Using this coupler allows a person to take part in a conference from a remote location even from overseas In addition to the units described above the following optional units are av...

Страница 5: ... 6 7 8 9 MONITOR MIC LINE 1 MIC LINE 2 MIC LIMIT ON OFF DIRECT ACCESS ON OFF SEAT ASIGN START END D C UNIT SP 0 10 1 2 3 4 5 6 7 8 9 0 10 1 2 3 4 5 6 7 8 9 0 10 1 2 3 4 5 6 7 8 9 D C UNIT MIC ORIGINAL a You can also use other combination of the SX C150 SX D150 SX D100A Delegate s Unit a SX C100A Chairman s Unit a Conference seats Operator section SX T100 Telephone Coupler SX M100 Control Unit ...

Страница 6: ...MIC LINE 2 D C UNIT SP 0 10 1 2 3 4 5 6 7 8 9 0 10 1 2 3 4 5 6 7 8 9 0 10 1 2 3 4 5 6 7 8 9 D C UNIT MIC ORIGINAL IN EXT UNIT OUT MIC Front panel 2 PHONES connector 4 Level meter 3 MONITOR volume control 1 POWER switch 5 Volume controls 7 DIRECT ACCESS ON OFF button 6 MIC LIMIT ON OFF button 8 SEAT ASSIGN START END button 9EXT UNIT IN OUT connectors LINE OUT connector TELEPHONE COUPLER connector 0...

Страница 7: ... MIC microphone LIMIT ON Press this button to set the microphone to the speaker s number limitation mode The button indicator lights Setting this mode allows the microphones of up to five delegate s units to be live at the same time MIC microphone LIMIT OFF Press the button again to set the microphone to the speaker s number unlimitation mode The button indicator goes out Setting this mode allows ...

Страница 8: ...ransmitter by means of an infrared or induction based system TELEPHONE COUPLER connector 6 pin multi connector Connect to the SX T100 telephone coupler not supplied EXT IN 2 MIC LINE external 2 microphone line signal input connectors and MIC LINE microphone line signal select switch EXT IN 2 MIC LINE connectors Input an external audio signal MIC connector phone jack Connect a rostrum or conference...

Страница 9: ...onding to the numbered parts and controls in the illustration SX C100A SX D100A Chairman s Unit Delegate s Unit Chairman unit front panel Chairman s unit delegate s unit side panel VOL PRIORITY VOL MIC ON OFF 4 4 MIC ON OFF 1 Output connector 2 Microphone and microphone indicator 3 Speaker 9 REC OUT connector 1 Output connector 3 Speaker 4 VOL control Delegate s unit front panel 4 VOL control 5 Ca...

Страница 10: ...d indicator 7 PRIORITY button and indicator ºEarphone jacks 4 VOL control 2 Microphone and microphone indicator 3 Speaker Delegate s unit top 9 REC OUT connector MIC ON OFF 2 Microphone and microphone indicator 8 MIC ON OFF button and indicator 4 VOL control ºEarphone jacks 3 Speaker Chairman unit delegate s unit bottom 1 Output connector 5 Input connector 6 Voting connector ...

Страница 11: ...for about 3 seconds to tell the user that the microphone cannot be enabled since the number of units whose MIC ON OFF button is pressed exceeds six The explanations given here apply to both units unless noted otherwise with the exception of PRIORITY button 7 1 Output connector For SX C100A SX D100A 20 pin multi connector Connect the cable with a 20 pin multi connector of the chairman s unit delega...

Страница 12: ... 9 REC OUT recording output connector minijack Connect to the input connector of the tape recorder to record the monitor sound Note Use a connecting cable with a terminating resistor RK G64 and so on to connect the unit to the microphone input connector of a tape recorder Use a connecting cable without a terminating register RK G69 and so on to connect the unit to the line input connector of a tap...

Страница 13: ... Note If the handset is not secured firmly communication may not be satisfactory 1 CONTROL UNIT connector 6 pin multi connector Connect to the TELEPHONE COUPLER connector of the SX M100 Control Unit using the connecting cord supplied with the SX T100 2 Power indicator This indicator lights when the telephone coupler power is turned on 3 POWER ON OFF switch Turns the telephone coupler power on or o...

Страница 14: ...hone indicators and MIC ON OFF buttons continue to blink and these units cannot be controlled by the control unit In such a case turn the power off then back on again When using the DELEGATE S CHAIRMAN S UNIT connectors of the SX M100 Control Unit attach the dust caps removed from the 20 pin multi connectors on the control unit to the 20 pin multi connectors on the last unit connected If the 20 pi...

Страница 15: ...connected to one line a For details of connecting cables see How to connect cables shown below b You can extend the distance between units by using the RK 1710 1713 connecting cable not supplied c The desk mounted SX C150 SX D150 can also be used in this system Up to 15 desk mounted SX C150 and SX D150 units can be connected to one line The specially designed cables are used to connect these units...

Страница 16: ...ch of the control unit to ON 3 When necessary set the POWER switch of the telephone coupler to ON 2 VU I O POWER PHONES ON OFF MONITOR MIN MAX 1 2 3 4 5 6 7 8 9 0 10 1 2 3 4 5 6 7 8 9 MONITOR MIC LINE 1 MIC LINE 2 MIC LIMIT ON OFF DIRECT ACCESS ON OFF SEAT ASIGN START END D C UNIT SP 0 10 1 2 3 4 5 6 7 8 9 0 10 1 2 3 4 5 6 7 8 9 0 10 1 2 3 4 5 6 7 8 9 D C UNIT MIC ORIGINAL 3 Control unit Telephone...

Страница 17: ...ilter unit not supplied Note The person speaking into the microphone should bring his her mouth close to the microphone Control unit Chairman s unit delegate s unit Preparing the Control Unit Adjusting the audio level Adjust the audio signal output to the chairman s delegate s unit and input from the external equipment connected to EXT IN 1 2 before the conference Adjusting the output level of the...

Страница 18: ... whether the number of speakers is limited according to the conference type To limit the number of speakers to five Press the MIC LIMIT ON OFF button such that the button indicator lights Note When the power of the control unit is turned off the MIC LIMIT ON OFF button is automatically reset to OFF even if it has been set to ON To set the mode to limit the number of speakers to five after the powe...

Страница 19: ...te is listening through the speaker the speaker is turned off and the volume levels of the speakers of the units on both sides of the unit are also automatically reduced while the microphone is enabled Upon finishing speaking Upon finishing speaking press the MIC ON OFF button again The MIC ON OFF button indicator and the microphone indicator go out and the microphone is disabled To listen the sou...

Страница 20: ...hone connection with the party who will take part in the conference 3 Place the handset on the telephone coupler after the other party answers the phone The handset catch part is movable Adjust the coupler to the handset size and secure the handset with the handset securing tape The called person can now take part in the conference Notes Orient the handset correctly If the handset is not adjusted ...

Страница 21: ...he connecting cable may be broken Disconnect the first unit of those whose indicator and button are blinking When the indicator and button of the subsequent units stop blinking and go out it indicates that the disconnected unit was defective Remove it from the system or replace it with a functioning unit When the indicator and button continue to blink even after removing the first unit the connect...

Страница 22: ...z Accessory supplied Connecting cord 1 Design and specifications are subject to change without notice SX M100 Control Unit Input output connectors DELEGATE S CHAIRMAN S UNIT 20 pin multi connector 4 TELEPHONE COUPLER 6 pin multi connector 1 Input EXT IN 1 EXT IN 2 MIC XLR 3 pin connector 1 Balanced type input level 0 77 mV 60dBs for microphone having low impedance MIC phone jack 1 Unbalanced type ...

Страница 23: ...23 ...