34
Power Requirements
AITi390, AITi520
Voltage
Max Ripple
Current
Typical
Maximum
5 V +/– 5 %
100 mVp-p
1.5 A
2.5 A
12 V +/– 10 %
150 mVp-p
0.75 A
3.0 A
AITi260
Voltage
Max Ripple
Current
Typical
Maximum
5 V +/– 5 %
100 mVp-p
1.6 A
1.9 A
12 V +/– 10 %
150 mVp-p
0.5 A
1.2 A
AITi130
Voltage
Max Ripple
Current
Typical
Maximum
5 V +/– 5 %
100 mVp-p
1.1 A
1.4 A
12 V +/– 10 %
150 mVp-p
0.4 A
1.2 A
AITi90
Voltage
Max Ripple
Current
Typical
Maximum
5 V +/– 5 %
100 mVp-p
1.1 A
1.4 A
12 V +/– 10 %
150 mVp-p
0.4 A
1.2 A
Air-cooling Requirement
Surrounding temperature
< 40 ˚C (104 ˚F)
Clean air flow is recommended to minimize the possibility of data loss.
Humidity
Operating
20 to 80% RH, non-condensing
Maximum wet bulb temperature :
26 ˚C (78.8 ˚F)
Non-Operating (mech.) 5 to 95% RH (
∆
RH<30%/h)
Maximum wet bulb temperature :
45 ˚C (113 ˚F)
Non-Operating (tape)
20 to 80% RH (
∆
RH<30%/h)