- SS-HQ1 Application Notes -
Ver.1.0.0 January 7, 2005
225
12.2.14. Phase Adjustment Using the Shifter
SFTV and SFTH in
are parameters which are controlled using the keys (SFTUP, SFTDWN) for
phase adjustment.
The particular parameters which can be controlled differ depending on the external synchronization mode.
* For information on key operations (SFTUP, SFTDWN), see 12.3 (“Key Operations (Shifter)”).
Table 12.2-32 Parameters Controlled by Key Operations
Parameter
Description
SFTHL CAT7_Byte3_bit0-7
Horizontal
direction phase adjustment value(LSB)
SFTHM CAT7_Byte5_bit0-1
Horizontal
direction phase adjustment value(MSB)
SFTVL CAT7_Byte4_bit0-7
Vertical
direction phase adjustment value(LSB)
SFTVM CAT7_Byte5_bit2-3
Vertical
direction phase adjustment value(MSB)
Parameters controlled by keys
shows the SFTV and SFTH parameters which are controlled by keys in the various external
synchronization modes.
Values which are adjusted through key operations are saved to the parameters in
. Saved values
(written to EEPROM when a key is released) are applied to SFTV/SFTH during initialization and when the
external synchronization mode is switched.
Table 12.2-33 Parameters Controlled by Keys in Each External Synchronization Mode
External
Synchronization Mode
SGMODE
(CAT17_Byte17_bit0-3)
Parameters Controlled
by Keys
INT 0[h] -
LL 1[h]
SFTVL/M
VSL 2[h]
SFTHL/M
VBSLHP 3[h] SFTHL/M
VBSLHR 4[h] SFTHL/M
VRHR 5[h]
-
VSL-S A[h]
SFTHL/M
VSL-D F[h]
SFTHL/M
Table 12.2-34 Parameters for Saving SFTV/SFTH Adjustment Values
Parameter
Description
CTRLSFTHL CAT17_Byte1_bit0-7
Parameter for saving SFTH adjustment value
when key is released (LSB)
CTRLSFTHM CAT17_Byte2_bit0-1
Parameter for saving SFTH adjustment value
when key is released (MSB)
CTRLSFTVL CAT17_Byte3_bit0-7
Parameter for saving SFTV adjustment value
when key is released (LSB)
CTRLSFTVM CAT17_Byte4_bit0-1
Parameter for saving SFTV adjustment value
when key is released (MSB)