Bulletin No.: 036
19
th
February, 2013
SRX-R515P
DCinema Bulletin Archive:
https://filex.sony-europe.com/
Login and navigate to
Dealers/Digital Cinema Bulletins
folder
Connecting
R515
to
a
Windows
storage
device
The diagram below shows a typical example of a storage device connected to 2x SRX-
R515P projectors.
SRX
‐
R515
XCT
‐
M10
(IMB)
XCT
‐
S10
(Server)
SRX
‐
R515
XCT
‐
M10
(IMB)
XCT
‐
S10
(Server)
Gb
NETWORK
SWITCH
PRJ
NETWORK
PRJ
NETWORK
CTRL
DATA
CTRL
DATA
Server
Storage
with
XXTB
Projector
1
CTRL
Port
IP
– 192 .168 .101 .11
DATA
Port
IP
– 192.168.201.11
Projector
2
CTRL
Port
IP
– 192.168.101.12
DATA
Port
IP
– 192.168.201.12
NB.
DATA
port
IP
Address
must
be
on
a
different
subnet
to
the
CTRL
port
IP
Address .
The
Switch
can
be
configured
for
separate
VLANs
for
the
control
and
data
traffic .
This
is
up
to
the
installer /customer
preference .
If
the
Storage
device
has
two
NICs
you
may
wish
to
set
one
to
the
CTRL
subnet
and
the
other
to
the
DATA
subnet .
If
only
one
NIC
is
available
set
two
IP
addresses
for
the
one
NIC .
Server
CTRL
IP
– 192.168.101.5
DATA
IP
– 192.168 .201 .5
Figure 3 - Network Storage connection example
The XCT-S10 requires that the CTRL IP address and the DATA IP address are required to
be on separate subnets. This can be used to separate CTRL and DATA traffic through the
use of VLANs on a switch.