SRP-X500P RS-232C Interface Manual
♦
Parameter
The parameter consists of 16 bytes of data in the order shown in the following table.
Byte Parameter
1st
MIC 1/WL 1 INPUT LEVEL METER
2nd
MIC 2/WL 2 INPUT LEVEL METER
3rd
MIC 3 INPUT LEVEL METER
4th
MIC 4 INPUT LEVEL METER
5th
LINE INPUT L LEVEL METER
6th
LINE INPUT R LEVEL METER
7th
AV/RGB INPUT L LEVEL METER
8th
AV/RGB INPUT R LEVEL METER
9th
SPEAKER OUTPUT 1 LEVEL METER
10th
SPEAKER OUTPUT 2 LEVEL METER
11th
SPEAKER OUTPUT 3 LEVEL METER
12th
SPEAKER OUTPUT 4 LEVEL METER
13th
LINE OUTPUT 1 LEVEL METER
14th
LINE OUTPUT 2 LEVEL METER
15th
LINE OUTPUT 3 LEVEL METER
16th
LINE OUTPUT 4 LEVEL METER
•
LEVEL METER (1st-16th byte)
Indicates the level meter reading (in VU units).
The parameter and the level meter reading are as shown in the following table.
Level meter
reading
Level
meter
reading
Less than -30
0x30 (‘0’)
-4
0x39 (‘9’)
-30
0x31 (‘1’)
-3
0x3A (‘:’)
-20
0x32 (‘2’)
-2
0x3B (‘;’)
-15
0x33 (‘3’)
-1
0x3C (‘<‘)
-10
0x34 (‘4’)
0
0x3D (‘=‘)
-8
0x35 (‘5’)
1
0x3E (‘>‘)
-7
0x36 (‘6’)
2
0x3F (‘?’)
-6
0x37 (‘7’)
3 or more
0x40 (‘@’)
-5 0x38
(‘8’)
Page 22/43