– 17 –
1
VCO/TX FREQ. ADJ
L
L
L
L
IN
L
H
2
TX MOD CHECK
L
H
L
L
IN
H
L
3
TX DATA
L
L
L
L
IN
L
H
*1
4
RX SENS
H
L
H
L
IN
H
L
5
SQ SENS
L
L
*A
L
IN
H
L
6
BELL CHECK
H
L
L
L
L/IN
H
H
*2
7
DTMF DUAL TONE
H
L
L
L
IN
H
L
*3
8
DATA IN CHECK
L
L
L
L
IN
L
L
*4
9
CHARGE CHECK
H
L
L
L
IN
L
H
*5
10
DUPLEX
L
H
H
L
IN
H
L
11
INTERCOM
L
H
H
H
L
L
H
12
DTMF SINGLE TONE
H
L
L
L
IN
H
L
*6
[Test Mode Execution]
Press the
[INTERCOM]
key to execute any of the following tests:
*Initial Channel of each step: 19CH
*A. SQ on: H (CHARGE LED turns on)
SQ off: L (CHARGE LED turns off)
*1. Test Mode 3: Continue output TX data as “ 0000……”.
*2. Test Mode 6: Output level of the bell can be changed by the
[RINGER]
switch (S2).
*3. Test Mode 7: When the base unit status changes to charge on (more than 500 msec.) from
charge off conditions, DTMF will be changed.
1
→
2
→
3
→
4
→
5
→
6
→
7
→
8
→
9
→
0
→
→
#
→
1
→
…… .
*4. Test Mode 8: When locked receiving data is “ 0000……”, CHARGE LED turns on.
*5. Test Mode 9: When CHGIN (IC8 pin
wf
) is “ L” (charge on), CHARGE LED turns on.
*6. Test Mode 12: When the base unit status changes to charge on (more than 500 msec.) from
charge off conditions, DTMF will be changed.
ROW 0
→
ROW 1
→
ROW 2
→
ROW 3
→
COL0
→
COL1
→
COL2
→
ROW0
→
…… .
* DTMF frequency
ROW 0: 696.95 Hz
COL0: 1209.31 Hz
ROW 1: 770.13 Hz
COL1: 1335.65 Hz
ROW 2: 852.27 Hz
COL2: 1476.71 Hz
ROW 3: 940.99 Hz
*
Step
Test Mode
Name
TX CONT (IC8 pin
ej
)
RX MUTE (IC8 pin
qg
)
MIC MUTE (IC8 pin
qj
)
Remar
ks
TX MUTE (IC8 pin
qh
)
SP MUTE (IC8 pin
wg
)
RL CONT (IC8 pin
wh
)
LINE MUTE (IC8 pin
rk
)
Содержание SPP-A946
Страница 3: ... 3 SECTION 1 GENERAL This section is extracted from instruction manual ...
Страница 4: ... 4 ...
Страница 5: ... 5 ...
Страница 6: ... 6 ...
Страница 7: ... 7 ...
Страница 8: ... 8 ...
Страница 9: ... 9 ...
Страница 10: ... 10 ...
Страница 11: ... 11 ...
Страница 12: ... 12 ...
Страница 35: ...SPP A946 A947 45 46 5 12 SCHEMATIC DIAGRAM HAND RF Section Page 49 Page 49 Page 49 ...