– 9 –
IC501
IC101
TP35
TP36
TP55
TP33
TP44
TP43
TP14
TP13
TP16
TP15
TP17
– hand main board (side B) –
HANDSET SECTION
MANUAL TEST MODE
Set the Test Mode:
1. Enter the test mode by pressing 0 key while pressing 1 and
TALK keys when in idle condition.
(Key operation 0
n
1
n
TALK )
2. The RINGER will ring for 500 msec. when the test mode is
started.
3. Measurement mode of consumption current. (42# state)
4. Use key input to carry out the various settings.
5. Use port inputs to set output from LED terminals.
Release the Test Mode:
1. Press the 0 , 0 and # keys.
2. Turn off the power. (Remove the battery and replace them.)
MACHINE TEST MODE
Set the Test Mode:
1. When power on reset is applied while a “H” (high) is input the
TEST SW (TP43) terminal (IC501
$º
pin), the RING (Level
H, 500 msec) sounds.
2. Following that, at timing in which the TEST SW terminal has
“H” (high) input, there is output of “L” (low) by the CH
(channel) setting control terminal. Then there is PLL setting to
the CH which was read to with the CH setting terminal
according to that “L” (low) output.
3. Set the TX setting to TX OFF.
4. The channel is set by voice not by data.
5. Use port inputs to set output from LED terminals.
Release the Test Mode:
1. Press the OFF key.
2. Remove the short plug and turn on the power.
Содержание SPP-111 - Cordless Phone Page
Страница 3: ... 3 SECTION 1 GENERAL This section is extracted from instruction manual ...
Страница 4: ... 4 ...
Страница 5: ... 5 ...
Страница 21: ...SPP 111 5 5 SCHEMATIC DIAGRAM BASE UNIT SECTION 2SC1623 L5L6 25 26 ...
Страница 23: ...SPP 111 5 7 SCHEMATIC DIAGRAM HANDSET SECTION Refer to page 24 for Note 29 30 ...