11

Testing the network connection

The ping command can be used to check the connection 
between two IP addresses. This allows testing whether a 
device is active in the network.

1

Open the DOS command prompt.

2

Type 

ping

 followed by the IP address of the device.

If the device is found, the response appears as “Reply from 
... ”, followed by the number of bytes sent and the 
transmission time in milliseconds. Otherwise, the device 
cannot be accessed via the network. This might be 
because:
– The device is not properly connected to the network. 

Check the cable connections in this case.

– The device is not correctly integrated into the network. 

Check the IP address, subnet mask, and gateway address.

Customer service

If a fault cannot be resolved, please contact your supplier 
or system integrator.
The version numbers of the internal firmware can be 
viewed on a service page. Please note this information 
before contacting Customer Service.

1

In the address bar of your browser, after the unit IP 
address, enter: /version 
for example: 192.168.0.80/version

2

Write down the information or print out the page.

Maintenance

Cleaning

It is generally sufficient to use a dry cloth for cleaning, but 
a moist lint-free cloth or leather shammy may also be used.
Do not use liquid cleaners or aerosol cleaners.

Lens cleaning

It is important to keep the lens clean to ensure optimum 
performance. Dust, grease, or fingerprints should be 
removed from the lens surface. When cleaning the lens, 
take extra care not to damage the special coating used to 
reduce light reflections.
– Remove dust with a blower-brush or grease-free soft 

brush.

– Wipe water drops off the lens with a clean soft lint-free 

cloth and dry the lens surface.

– Use special lens cleaning paper or cloth treated with lens 

cleaning fluid to gently wipe off any remaining dirt 
(wipe spirally from the lens center towards the edge).

Repair

Warning

Never open the casing of the unit.

The unit does not contain any user-serviceable parts. Refer 
all repairs to suitable qualified specialists.

Reset

Use the factory reset button to restore the unit to its original 
settings. Any changes to the settings are overwritten by the 
factory defaults. A reset may be necessary, for example, if 
the unit has invalid settings that prevent it from functioning 
as desired.

Push

Reset

Содержание SNC-HMX70

Страница 1: ...Network Camera Installation Manual Before operating the unit please read this manual thoroughly and retain it for future reference SNC HMX70 4 744 488 11 2 2018 Sony Corporation ...

Страница 2: ...Installation 5 Local storage 5 Ceiling mount 5 Wall mount 6 Removing the camera 7 Network connection 8 Network and PoE power 8 Configuration 9 Browser connection 9 Troubleshooting 9 LED status overview 9 Resolving problems 10 Testing the network connection 11 Customer service 11 Maintenance 11 Cleaning 11 Repair 11 Reset 11 Specifications 12 Dimensions 15 ...

Страница 3: ...ll benefit from the discreet design The camera is easily mounted to any surface using a twist click mechanism via the supplied mounting ring The high quality IR corrected lens is factory focused and is not restricted by a bubble so installation is simplified and sharpness is assured The LED indicators reset button and SD card slot are easily accessed via two hinges at the front of the camera A com...

Страница 4: ...ce Contents The packaging contains SNC HMX70 Panoramic Camera Safety Regulations Identification labels Mounting ring 2 Allen keys T10 and 1 5 4 screws 4 5 40 4 plugs 2 washers M4 14 for mounting to 4s box System requirements To enjoy the full benefits of megapixel resolutions ensure that the computer the graphic adapter the display connections and the monitor are sufficiently powerful to view our ...

Страница 5: ...rclockwise to lock the card into place Ceiling mount Mount flush to ceiling To flush mount the camera in a ceiling 1 Use the mounting ring to mark out the recess hole and to mark the four mounting holes The mounting holes PCD is 133 mm 5 1 4 in 2 Cut out the inner recess hole Ø105 mm 4 1 4 in 3 Drill four holes with a diameter of 6 mm 1 4 in 4 Insert the supplied mounting plugs 6 30 into the holes...

Страница 6: ...m 1 4 in 3 Insert the supplied mounting plugs 6 30 into the holes 4 Use the supplied screws 4 5 40 to securely attach the SMB to the surface 5 Use the four screws M5 to attach the mounting ring to the SMB 6 Attach the camera body to the mounting ring as described above Wall mount Use the Surface mount box SMB to mount the camera on a wall as described above It is however very important to pay atte...

Страница 7: ... into the opening above the access flaps to open them push straight do not wobble 2 Using the T10 Allen key turn each mounting screw four full turns counterclockwise to loosen them Remove camera 1 Turn the camera counterclockwise to disconnect it from the mounting ring 2 Disconnect the Ethernet cable and remove the camera 90 0 180 270 Top N Top T10 T10 Push Push 4 4 1 2 ...

Страница 8: ...tighten them this resets the mounting clips 2 Close the flaps Network connection Network and PoE power Connect the camera to a 10 100 Base T network Use STP Category 5e cable with RJ45 connectors the camera network socket is Auto MDIX compliant Power is supplied to the camera via the Ethernet cable compliant with the Power over Ethernet standard Caution Use only PoE approved devices T10 T10 4 4 ...

Страница 9: ...b browser 2 Enter the IP address of the unit as the URL 3 During initial installation confirm any security questions that appear Protected network If a RADIUS server is used for network access control 802 1x authentication the unit must be configured first To configure the unit connect it directly to a computer using a network cable and configure the two parameters Identity and Password Only after...

Страница 10: ... Incorrect configuration Check audio parameters on the Audio configuration and LIVE page functions pages The audio voice connection is already in use by another receiver Wait until the connection is free and then call the sender again The unit does not report an alarm Alarm source is not selected Select possible alarm sources on the Alarm sources configuration page No alarm response specified Spec...

Страница 11: ...e down the information or print out the page Maintenance Cleaning It is generally sufficient to use a dry cloth for cleaning but a moist lint free cloth or leather shammy may also be used Do not use liquid cleaners or aerosol cleaners Lens cleaning It is important to keep the lens clean to ensure optimum performance Dust grease or fingerprints should be removed from the lens surface When cleaning ...

Страница 12: ...amic range 92 dB WDR 16 dB IAE Video streaming Video compression H 264 MP M JPEG Streaming Multiple configurable streams in H 264 and M JPEG configurable frame rate and bandwidth Multiple channels with edge dewarping Regions of Interest ROI Overall IP Delay Min 120 ms Max 340 ms Encoding interval 1 to 25 30 ips Video resolution H V 360 version Video 1 channel Full image circle 2640 2640 Video 2 ch...

Страница 13: ...OTION Pre positions Six independent sectors Display stamping Individual names and stamps for all video channels Other functions Pixel counter Video watermarking Location Optical Lens 360 version 1 6 mm fixed focus lens IR corrected F2 8 Lens mount Board mounted Iris control Fixed iris Field of view 360 version 180 H 180 V Minimum object distance 0 1 m 4 in Day Night Switched mechanical IR filter A...

Страница 14: ...iffServ QoS LLDP SOAP Dropbox CHAP digest authentication Encryption TLS 1 2 SSL DES 3DES Ethernet 10 100 Base T auto sensing half full duplex Connectivity ONVIF Profile S Auto MDIX Mechanical Dimensions 158 33 mm 6 1 4 1 5 16 in Weight 526 g Environmental Operating Temperature 20 C to 40 C 4 F to 104 F Storage Temperature 20 C to 60 C 4 F to 140 F Operating humidity 20 to 93 RH Storage humidity up...

Страница 15: ...15 Dimensions N S W E 34 1 3 8 68 2 3 4 105 4 1 4 158 6 1 4 mm inches 150 6 NPT 3 4 PG16 158 6 1 4 47 1 7 8 mm inches ...

Страница 16: ...Sony Corporation ...

Отзывы: