6-4
2-4-2.
SYNC AGC Check (MA-316 Board)
Mode
E-E
Signal
Color bar
Measurement point
IC201 pin
#•
Measuring instrument
Oscilloscope
Specified value
A=2.1 ± 0.1Vp-p
[Check Method]
1)
Check that the Video signal level (A) satisfies the specified
value.
Fig. 6-2-6
2-4-3.
White Clip/Dark Clip Check (MA-316 Board)
Mode
E-E
Signal
Color bar
Measurement point
IC201 pin
#¶
Measuring instrument
Oscilloscope
Specified value
White clip : 190 ± 15%
Dark clip : 58.5 ± 5%
Connect a resistor of 3.3k
Ω
between IC201 pin
$™
and GND.
[Check Method]
1)
Check that the white clip level is 190 ± 15% to the white (100%)
level.
2)
Check that the dark chip level is 58.5 ± 5% to the white (100%)
level.
2-4-4.
Recording Y Level Check (MA-316 Board)
Mode
E-E
Signal
No-signal
Measurement point
IC201 pin
!•
Measuring instrument
Oscilloscope
Specified value
A=307 ± 50mVp-p
[Check Method]
1)
Check that the recording RF signal satisfies the specified value.
Fig. 6-2-8
2-4-5.
Recording Chroma Level Check
(MA-316 Board)
Mode
Recording
Signal
Color bar
Measurement point
IC201 pin
!¢
Measuring instrument
Oscilloscope
Specified value
A=350 ± 40mV
[Check Method]
1)
Confirm the amplitude of recording chroma level becomes the
specified value.
Fig. 6-2-9
A
H
A
B
White (100%)
A
A
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299