5-8
SEL1635GM
6. Start the lens adjustment program “BLG-TestProgramV
[][][]
.exe”.
7. When [Open] is clicked and communication between personal computer and B-L Control Box is connected, the button name changes to
[Close] and the [Power] button is made active.
8. Click [Power] to supply power to the lens to be tested.
At this time, confirm that both of the two LEDs on the B-L Control Box are light.
(If either or none of them does not light, there is a problem.)
LEDs for power supply check
B-L Control Box
Power switch
Note 1:
Before detaching the lens after power is supplied, be sure to
click [Power] again and con
fi
rm that the two LEDs go out.
9. Select “Center Hold” from the steady shot selection menu, and click [Steady Shot].
Steady Shot setting: Center Hold