4.Operation
4-4
SONY AIT-3 drive SDX-700 series Ver.2.1
4.3.3.
Power-Fail or SCSI Reset Handling
If there is a power-fail, the SDX-700C performs the following actions, and reverts to its default configuration
:
(1)
The drive remains positioned at the point where the power-fail or SCSI Reset occurred.
(2)
It executes the Power-Up sequence of self-tests. (When power is restored.)
(3)
If a tape is in the drive, the SDX-700C starts a LOAD sequence. The drive rewinds the tape to BOT and
remains on-line.
(4)
The drive returns CHECK CONDITION status for the first command after the power-fail or Reset. The next
command from the initiator should be a REQUEST SENSE. The drive will return sense data including a sense
key that will indicate that the drive has been reset. (Sense Key / ASC / ASCQ = 06/29/00)
4.3.4.
Diagnostic and Normal Status Displays
This chapter describes LED displays while the SDX-700C is starting up. When power is turned on, the SDX-700C
will go through its diagnostics to reach normal status. When a failure is detected during diagnostics, the LEDs show
that the SDX-700C is out of order and needs to be repaired.
4.3.4.1.
Diagnostic Status Display
The SDX-700C starts with its Diagnostic function. This is made up of the Front Panel Test and the Kernel Test
.
Front Panel Test
LED display sequence
:
TAPE
CLEANING
REPLACE
MOTION
REQUEST
TAPE
0.3sec
on
on
on
0.3sec
-
-
-
0.3sec
on
on
on
0.3sec
-
-
-
Front Panel Test
0.3sec
on
-
-
0.3sec
-
on
-
0.3sec
-
-
on
0.3sec
on
-
-
0.3sec
-
on
-
0.3sec
-
-
on
0.3sec
on
-
-
This function is for checking BUSY, STATUS and TAPE LEDs and the related circuits. No errors can be generated
as this test is only for operator verification of indicator operation
.
Kernel Test
After the Front Panel Test, the SDX-700C checks its internal units. When a Diagnostic error occurs, the SDX-700C
must be powered off. The SDX-700C will not work and should be checked or repaired immediately.
The purpose of the diagnostic firmware to test the SDX-700C electronics for functionality. If the diagnostic request
comes from the host through SCSI, then the results are reported through SCSI.
If the electronics are not functioning, the diagnostic firmware tries to isolate the non-functional area to a specific
Failed Unit. Given a failure, the firmware decides on an hierarchical basis which Unit to designate as the Most
Suspect Failed Unit (MSFU). The confidence in this decision is intended to be 95%. For the details of Diagnostics,
see clause 7.2.6
Содержание SDX-700C
Страница 12: ...1 Introduction SONY AIT 3 drive SDX 700 series Ver 2 1 1 4 This page intentionally left blank ...
Страница 15: ...2 Specification SONY AIT 3 drive SDX 700 series Ver 2 1 2 3 Figure 2 2b SDX 700C R Mounting Holes ...
Страница 22: ...2 Specification SONY AIT 3 drive SDX 700 series Ver 2 1 2 10 This page intentionally left blank ...
Страница 28: ...3 Installation SONY AIT 3 drive SDX 700 series Ver 2 1 3 6 This page intentionally left blank ...
Страница 172: ...7 Drive Diagnostics 7 10 SONY AIT 3 drive SDX 700 series Ver 2 1 This page intentionally left blank ...
Страница 178: ...10 Appendix C 10 2 SONY AIT 3 drive SDX 700 series Ver 2 1 This page intentionally left blank ...
Страница 180: ...11 Appendix D 11 2 SONY AIT 3 drive SDX 700 series Ver 2 1 This page intentionally left blank ...
Страница 186: ...12 Appendix E SONY AIT 3 drive SDX 700 series Ver 2 1 12 6 This page intentionally left blank ...
Страница 196: ...13 Appendix F SONY AIT 3 drive SDX 700 series Ver 2 1 13 10 This page intentionally left blank ...