17

Interface Implementation

Supported SCSI Messages

Abort

Bus Device Reset

Command Complete

Disconnect

Extended Message

- Synchronous Data Transfer

Request

Identify (w/&w/o Disconnect)

Ignore Wide Residue

Initiator Detected Error

Message Parity Error

Message Reject

No Operation

Restore Pointers

Save Data Pointer

Supported SCSI Commands

Erase

Inquiry

Load/Unload

Locate

Log Select

Log Sense

Mode Select (6)

Mode Sense (6)

Prevent Allow Medium
Removal

Read

Read Block Limits

Read Buffer

Read Position

Receive Diagnostic Results

Release Unit

Report Density Support

Report Luns

Request Block Address

Request Sense

Reserve Unit

Rewind

Seek Block

Send Diagnostic

Space

Test Unit Ready

Verify

Write

Write Buffer

Write Filemarks

Содержание SDT 11000 - DDS Tape Drive

Страница 1: ...3 866 090 04 1 1998 Sony Corporation DDS Tape Drive SDT 10000 Series SDT 11000 Series User s Guide ...

Страница 2: ...rüstung erfüllt die Europäischen EMC Bestimmungen für die Verwendung in folgender folgenden Umgebung en Wohngegenden Gewerbegebiete Leichtindustriegebiete Diese Ausrüstung erfüllt die Bestimmungen der Norm EN55022 Klasse B Contents Introduction 4 Product Features 4 Precautions 5 Installation 6 SCSI Connection Setting the SCSI ID Option Switches 6 Option Switches DIP Switch 7 Mounting Holes 8 Remod...

Страница 3: ...rough Read After Write an additional level of Error Correction Code and other features The Sony SDT 10000 SDT 11000 drive stores data on tape using a standard format called DDS Digital Data Storage DDS 4 DDS 3 DDS 2 DDS DC and DCLZ formats These formats are used by many other DDS tape drive manufacturers providing a broad range of compatible tape drives The Sony SDT 10000 SDT 11000 is fully READ a...

Страница 4: ...pports SCSI 2 Sequential access Devices Command Set Read After Write RAW Frame Rewrite Function Three Levels of Error Correction Code ECC Quick Search Forward 115 times Reverse 155 times normal DDS 4 Read Write speed Random Read N Group Write Option DDS 2 DDS and DDS DC only Dual Partition Option SCSI Disconnection Arbitration Assuming 2 1 compression Actual capacity and transfer rate may vary sin...

Страница 5: ...dden increase in temperature a malfunction may occur Do not turn off the drive while a tape is inside the drive Transportation Keep the original packing materials for possible future shipments of the drive Be sure to remove any tapes from drive prior to transportation After removing the drive from the computer repack the drive into its original packaging Notice of SCSI Termination This SDT 10000 S...

Страница 6: ... 3 2 1 GND GND 12V 5V Power Connector 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SCSI ID SCSI ID P E R 3 2 1 0 Parity Enable Disable Note CLOSE Jumper OPEN Jumper not installed Don t care Parity Enable Reserved SCSI ID 3 SCSI ID 2 SCSI ID 1 SCSI ID 0 Jumpers SCSI 68 pin connector Non Shielded ...

Страница 7: ...erminator Power Definition OFF No provided ON Provided DC Control 1 DC Control 2 Definition OFF OFF Compression disabled at power on The host is allowed to control compression OFF ON Compression disabled at power on The host is not allowed to control compression ON OFF Compression enabled at power on The host is allowed to control compression ON ON Compression enabled at power on The host is not a...

Страница 8: ... 0 20 in 5 0 3mm depth 0 12 in 3 M3 depth 3mm 3 70 in 94 0 3mm 4 00 in 101 6 0 5mm 1 22 in 31 0 3mm 1 65 in 42 0 3mm 2 76 in 70 0 3mm depth 0 12 in 6 M3 depth 3mm 2 36 in 60 0 3mm 3 54 in 90 0 3mm 5 75 in 146 0 5mm 0 15 in 3 8 0 5mm 0 83 in 21 0 3mm 0 20 in 5 0 3mm 1 62 in 41 2 0 5mm depth 0 12 in 3 M3 depth 3mm ...

Страница 9: ...mm 2 76 in 70 0 3mm 3 12 in 79 2 0 3mm 2 00 in 50 7 0 3mm 5 50 in 139 6 0 4mm 5 87 in 149 0 5mm depth 0 12 in 6 M3 depth 3mm 4 M3 3 12 in 79 2 0 3mm 1 87 in 47 5 0 3mm 0 39 in 9 9 0 3mm 0 86 in 21 8 0 3mm 4 M3 3 12 in 79 2 0 3mm 1 87 in 47 5 0 3mm 1 62 in 41 2 0 5mm 0 86 in 21 8 0 3mm 0 39 in 9 9 0 3mm 0 28 in 7 0 3mm ...

Страница 10: ...Model to 3 5 Model You can remodel the SDT 10000 R and the SDT 11000 R 5 25 model to the SDT 10000 and the SDT 11000 3 5 model yourself 1 Remove the 2 screws for each side rail 2 Take the side rail off Side Rail L Side Rail R ...

Страница 11: ...11 Orientation 10 10 10 10 10 10 10 10 ...

Страница 12: ...12 Operation Location of 3 LEDs There are three LED indicators BUSY TAPE and STATUS and an EJECT button on the front panel of the unit Front Panel for 3 5 Standard Height BUSY TAPE STATUS ...

Страница 13: ...ne Loaded None SCSI Loaded None SCSI Drive Loaded None Loaded Write Protected None Loaded Cleaning Tape at EOM Loaded Error Rate Warning Cleaning Request Selftest Failure Waiting for Reset Waiting for Eject Not defined 3 5 sec on 0 5 sec off 1 pulse 0 25 sec on 2 pulse 0 25 sec on 0 5 sec off off on 0 25 sec on 0 25 sec off LED Indication for Drive Status ...

Страница 14: ...sponse to a SCSI Unload Command or by pressing the eject button By pressing Eject button the tape goes to BOM the drive unthreads it and ejects the cassette from the slot Write protecting a Cassette Cassettes can be write protected by sliding the tab on the back of the cassette open In this state data can be read from the tape but not written onto it Using your fingernail push the switch in the di...

Страница 15: ... the drive from the chassis or enclosure to allow access to the bottom and left side of the drive 2 Remove the drive s top cover to monitor the degree of tape slack throughout the process Note Never touch the inside of the drive when the top cover is opened Otherwise it may cause a trouble 3 Rotate the Loading Threading motor clockwise with a small screwdriver ex Phillips No 1 put into the plastic...

Страница 16: ...16 4 Continue the procedure until the tape is lifted out of the drive mechanism and ejected 5 Return the drive to a service station for repair ...

Страница 17: ...ject No Operation Restore Pointers Save Data Pointer Supported SCSI Commands Erase Inquiry Load Unload Locate Log Select Log Sense Mode Select 6 Mode Sense 6 Prevent Allow Medium Removal Read Read Block Limits Read Buffer Read Position Receive Diagnostic Results Release Unit Report Density Support Report Luns Request Block Address Request Sense Reserve Unit Rewind Seek Block Send Diagnostic Space ...

Страница 18: ...e The sound meter on A scale is located 1m in front of the center of the drive front panel Shock Operating No Data Loss Half Sine Performance 5 G Peak 3 ms 3 axes 3 directions Interval 10 seconds Non Operating No Device Damage Half Sine 90 G Peak 3 ms 30 G Peak 11 ms 3 axes 3 directions Specification Product Specifications Dimensions 3 5 Standard Height 5 25 Half Height Height 41 2 mm 1 62 in 41 2...

Страница 19: ...of data loss Temperature and Humidity Range Temperature Operating 5 C to 40 C T 10 C h Non Operating mech 40 C to 70 C T 20 C h Non Operating tape 40 C to 45 C T 20 C h Humidity Operating 20 to 80 RH non condensing Maximum wet bulb temperature 26 C Non Operating mech 5 to 95 RH RH 30 h Non Operating tape 20 to 80 RH RH 30 h Power Requirements Voltage Max Ripple Current Typical Maximum 5 V 5 100 mV...

Страница 20: ...7 869 6700 Corel 613 728 8200 NovaStor 805 579 6700 Palindrome 708 505 3300 ST Bernard Sofware 619 676 2277 Sytron 508 898 0100 Tapedisk 715 235 3388 Macintosh Cheyenne 516 484 5110 Corel 613 728 8200 Dantz 510 253 3000 NovaStor 805 579 6700 OS 2 Cheyenne 516 484 5110 Corel 613 728 8200 IBM 800 426 3333 NovaStor 805 579 6700 Sytron 407 333 7500 Windows Arcada 407 333 7500 Cheyenne 516 484 5110 Cor...

Страница 21: ...880 0080 HP Unix Cheyenne 516 484 3150 NovaStor 818 707 9900 Work Station Solutions 603 880 0080 AIX Unix Cheyenne 516 484 3150 Legato 415 812 6000 NovaStor 818 707 9900 Software Moguls 612 933 8790 Work Station Solutions 603 880 0080 Interactive Unix Sun Soft 310 348 8649 SGI Unix Software Moguls 612 933 8790 Work Station Solutions 603 880 0080 Novell UNIXware Novell 801 263 3500 Novell NLM Arcad...

Страница 22: ...9 FAX 416 499 8541 Sony Computer Peripherals Compornents Europe URL http www sonyisstorage com Electronics Devices Marketing Singapore A division company of Sony Electronics S Pte Ltd Enterprise Storage Solutions Dept 2 International Business Park 01 10 Tower One The Strategy Singapore 609930 TEL 65 6544 8000 FAX 65 6544 7390 Sony Corporation of Hong Kong Ltd Computer Peripheral Sales Marketing Di...

Страница 23: ...564 A C N 001 215 354 URL http www sony com au home asp E mail informatica ssp br sony com Sony Chile Ltda Av Kennedy 8017 Las Condes Santiago Chile TEL 02 210 6000 FAX 02 210 5417 Sony Taiwan Limited Computer Peripheral Dept Electronic Devices Marketing Taiwan Company Rm 1506 Top FL Chia Hsin Bldg No 96 Sec 2 Chung Shan N Rd Taipei Taiwan TEL 886 2 2522 3286 FAX 886 2 2562 4587 Sony Korea Corpora...

Страница 24: ...Printed in Japan ...