![Sony SA-W3800 Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/sony/sa-w3800/sa-w3800_service-manual_414045002.webp)
2
SA-W2500/W3000/W3800
SAFETY CHECK-OUT
(US model)
After correcting the original service problem, perform the
following safety checks before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs,
screws, and all other exposed metal parts for AC leakage. Check
leakage as described below.
LEAKAGE
The AC leakage from any exposed metal part to earth Ground
and from all exposed metal parts to any exposed metal part
having a return to chassis, must not exceed 0.5 mA (500
microampers). Leakage current can be measured by any one of
three methods.
1. A commercial leakage tester, such as the Simpson 229 or
RCA WT-540A. Follow the manufacturers’ instructions to
use these instruments.
2. A battery-operated AC milliammeter. The Data Precision
245 digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The “limit”
indication is 0.75 V, so analog meters must have an accurate
low-voltage scale. The Simpson 250 and Sanwa SH-63Trd
are examples of a passive VOM that is suitable. Nearly all
battery operated digital multimeters that have a 2V AC range
are suitable. (See Fig. A)
Fig. A. Using an AC voltmeter to check AC leakage.
0.15
µ
F
To Exposed Metal
Parts on Set
1.5k
Ω
AC
voltmeter
(0.75V)
Earth Ground
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK
0
OR DOTTED
LINE WITH MARK
0
ON THE SCHEMATIC DIAGRAMS
AND IN THE PARTS LIST ARE CRITICAL TO SAFE
OPERATION. REPLACE THESE COMPONENTS WITH
SONY PARTS WHOSE PART NUMBERS APPEAR AS
SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUB-
LISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ!!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE
0
SUR
LES DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES
PIÈCES SONT CRITIQUES POUR LA SÉCURITÉ DE
FONCTIONNEMENT. NE REMPLACER CES COMPOSANTS
QUE PAR DES PIÈCES SONY DONT LES NUMÉROS SONT
DONNÉS DANS CE MANUEL OU DANS LES SUPPLÉMENTS
PUBLIÉS PAR SONY.
SA-W2500
AUDIO POWER SPECIFICATIONS
For the U.S.A. model
POWER OUTPUT AND TOTAL HARMONIC
DISTORTION:
With 6 ohm loads, from 28 – 200 Hz; rated 60 W, minimum RMS power,
with no more than 1 % total harmonic distortion from 250 milliwatts to
rated output.
System
Type
Active Subwoofer, (magnetically shielded design)
Speaker unit
Woofer : 25 cm dia. (9
7
/
8
in.), cone type
Continuous RMS output
South American models
90 W (6 ohms, 80 Hz, 10% THD)
Other models
100 W (6 ohms, 80 Hz, 10% THD)
Reproduction frequency range 28 Hz – 200 Hz
High frequency cut-off frequency 50 Hz – 200 Hz
Phase selector
NORMAL, REVERSE
Inputs
Input jacks
LINE IN: input pin jack
SPEAKER IN: input terminals
Output jacks
SPEAKER OUT: output terminals
General
Power requirements
North American models: 120 V AC, 60 Hz
South American models: 120/220/240 V AC,
50/60 Hz
European models: 230 V AC, 50/60 Hz
Australian models: 240 V AC, 50 Hz
Korean models: 220 – 230 V AC, 50/60 Hz
Taiwan models: 110 V AC, 60Hz
Other models: 230 – 240 V AC, 50/60 Hz
Power consumption
70 W
Dimensions
Approx. 290
×
350
×
391 mm
(11
3
/
8
×
13
3
/
4
×
15
3
/
8
in.) (w/h/d)
Mass
Approx. 10 kg (22 lb 1 oz)
Supplied accessories
Foot pads (4)
Audio connecting cord
(1 phono – 1 phono), 2 m (6 ft 6
1
/
2
in.) (1)
Design and specifications are subject to change without notice.