2-8
VPL-CS5/CX5
2-4. Service Know-How
2-4-1. When the Prism Block Is Replaced
1.
Perform the V COM adjustment. (Refer to Section “2-
2. VCOM Adjustment”.)
2.
Write the GAMMA data of the prism block.
3.
Perform the white balance adjustment. (Refer to
Section “2-5. White Balance Adjustment”.)
2-4-2. When the C Board Is Replaced
n
If any board other than the C board is replaced, there is not
adjustment item.
1.
Install IC406 of the C board before replacement, into
the new C board.
2.
Enter the Factory Mode.
3.
Place this model on a flat worktable. Press the TILT
key on a flat table so that the lens shutter becomes
visible a little when viewed from the front of the
model.
4.
Operate the TILT
+
key and stop it at the point that the
lens shutter becomes invisible from the front.
5.
From this position, flip the TILT
+
key twice.
6.
Press the keys as follows
[ENTER]
→
[ENTER]
→
[P]
→
[MEMORY]
keys. (Memorizing
the adjustment value.)
7.
With the model being placed on a flat worktable, open
the lens shutter fully open while the adjuster does not
touch the ground.
8.
Write the X TILT value in C0 at this time.
9.
Point the model vertically upright and fix the position.
10. Write the X TILT value in C1 at this time.
11. Point the model vertically downward and fix the
position.
12. Write the X TILT value in C2 at this time.
13. Perform the V COM adjustment. (Refer to Section “2-
2. VCOM Adjustment”.)
14. If the white balance is significantly poor, perform the
white balance adjustment. . (Refer to Section “2-5.
White Balance Adjustment”.)
2-5. White Balance Adjustment
Preparation before adjustment
1.
Input the 100 IRE flat field signal to the INPUT-A
connector and allow the warm-up of 10 minutes aging
at a minimum.
2.
Enter the Service Mode.
Press the keys in the following order.
[ENTER]
→
[ENTER]
→
↑
→
↓
→
[ENTER]
.
The message [Do you want to enter the Service Mode?
Yes :
↑
No :
↓
] appears.
Select [Yes :
↑
].
[Supplementary information: How to Exit the
Service Mode]
Perform the step 2 KEY operation.
The message [Do you want to return to the User Mode?]
appears.
Select [Yes :
↑
].
2-5-1. HIGH Mode of INPUT-A
Connect the10-step signal to the INPUT-A connector and
measure the chromaticities at each brightness.
If chromaticities are different at each brightness, perform
the following adjustment.
1.
Input the 100 IRE flat field signal to the INPUT-A
connector.
2.
Measure the chromaticity (x, y).
3.
Input the 80 IRE flat field signal.
4.
Adjust the GAIN R and GAIN B in the HIGH mode of
W/B until the chromaticity (x, y) that is measured at
step 2 is obtained.
5.
Input the 30 IRE flat field signal.
6.
Adjust the BIAS R and BIAS B in the HIGH mode of
W/B until the chromaticity (x, y) that is measured at
step 2 is obtained.
7.
Repeat steps 3 to 6 until the chromaticity (x
±
0.002, y
±
0.004) with reference to the chromaticity (x, y) that
is measured at step 2 is obtained.
Содержание RM-PJM12
Страница 4: ......
Страница 8: ......
Страница 36: ......
Страница 40: ......
Страница 46: ...4 6 VPL CS5 CX5 Chassis VPL CS5 B 3x6 B 3x6 B 3x6 B 3x6 B 3x6 102 105 106 104 103 101 B 4x12 B 4x12 PWHTP 3x10 ...
Страница 80: ......
Страница 88: ......
Страница 124: ......
Страница 126: ...Sony Corporation B P Company 9 870 344 01 English 02FS16 1 Printed in Japan 2002 6 ...