![Sony REVDN700-2 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/sony/revdn700-2/revdn700-2_instruction-manual_418152016.webp)
live mode. So not only reducing the recording data but also not to miss object
movement.
-
No Motion(s)
: Adjust Interval while no motion.
-
Motion (0.1s)
: Adjust Interval while motion exists.
<System Setup>
1) General
- Cam Info
: Display camera basic information.
NOTE:
* Cam ID/Baud rate/Protocol/Lens Type/CCD Type/Video System/Firmware Version
-
System Lock
: System locking by 4-characters PID (Lock/Unlock)
-
Change PID
: Change PID used in the system lock.
NOTE:
* Enter PID: Input previous password. Default PID is “0000”.
* Enter New PID: Input new password.
* Retype New PID: Confirm of new password.
- Title
: Change camera title. Max. 8-characters.
- Display
: Configurations for display camera ID&title.
Cam ID
: Select camera ID display on/off.
Title
: Select title display on/off.
Display Pos
: Change position the string location.
- Language
: Change menu&OSD language.
2) Setup Tools
-
System Config
Multi-Camset
: Select On (User can use 4 configuration sets)/off
Video Analytics
: Select PVA mode. (Simple PVA/ PVA+)
Communication
: Configuration for RS-485.
Cam ID
: Select the camera ID (001 - 255).
Baud Rate:
Select serial communication speed (2400/4800/9600/19200).
Protocol
: RS-485 protocol. (Auto, FASTRAX/PELCO-D/PELCO-P)
Event Out
: Off, Text-Out, FxLink
Event Strings
: Select&edit sending strings for PVA/PVA+ Events.
NOTE:
* Text Out: Send event string through RS-485 line.
This function can work with IDIS DVR’s Text-in feature.
* FxLink: Send event to PC application.
- WPC (White Pixel Compensation)
: Compensation for defected pixel on CCD.
NOTE:
* While operating on WPC, Iris will be closed automatically if you using DC/IRIS Lens.
For manual lens, you have to block the lens hole.
Static/Auto
: Automatic detecting for defected pixel & compensation.
Proceeding
: Doing detection for white pixel.
NOTE:
* If brightness is too high, stop the process and print message “Bright Too High”.
* This function can compensate max. 63 points.
* If detected points are more than 63 points, repeats this detection by changes conditions.
* If more than 63 point while changing conditions, stop the process, and print “Too Many WH