RB1G
CHASSIS
W600A/ W603A/ W605A/ W607A/ W650A/ W651A/ W653A/
W654A/ W655A/ W656A/W657A/ W658A/ W670A/ W674A
6
1-4.Leakage Test
The AC leakage from any exposed metal part to earth ground and from all
exposed metal parts to any exposed metal part having a return to chassis must
not exceed 0.5mA (500 microamperes).
Leakage current can be measured by any one of the three methods:-
1) A commercial leakage tester such as the SIMPSON 229 or RCA WT540A.
Follow the manufacturers instructions to use those instructions.
2) A battery-operated AC milliampmeter The DATA PRECISION 245 digital
multimeter is suitable for this job.
3) Measuring the voltage drop across a resistor by means of a VOM or battery
operated AC voltmeter. The 'limit' indication is 0.75V so analog meters must
have an accurate low voltage scale. The SIMPSON'S 250 and SANWA SH-
63TRD are examples of passive VOMs that are suitable. Nearly all battery
operated digital multimeter that have a 2 VAC range are suitable.
(see Figure 2.)
1-3 Safety Check-Out
After correcting the original service problem, perform the following
safety checks before releasing the set to the customer:-
1) Check the area of your repair for unsoldered or poorly soldered
connections. Check the entire board surface for solder splashes and bridges.
2) Check the inter board wiring to ensure that no wires are pinched or
contact high-wattage resistors.
3)Check all control knobs, shields, covers, ground straps and mounting
hardware have been replaced. Be absolutely certain you have replaced all
the insulators.
4) Look for unauthorized replacement parts, particularly transistors that
were installed during a previous repair. Point them out to the customer and
recommend their replacement.
5) Look for parts which, though functioning show obvious signs of
deterioration. Point them out to the customer and recommend their
replacement.
6) Check the line cords for cracks and abrasion. Recommend the
replacement of any such line cord to the customer.
7) Check the antenna terminals, metal trim, metalized knobs, screws and all
other exposed metal parts for AC leakage. Check leakage test as described
next.
8. For safety reasons, repairing the Power board and/or Inverter board is
prohibited.
Figure 2. AC voltmeter to check AC leakage
Safety Notes
Содержание RB1G
Страница 2: ...LCD TV RB1G CHASSIS Segment LW SERVICE MANUAL COMMON Pravin Mevada ...
Страница 397: ...RB1G CHASSIS W600A W603A W605A W607A W650A W651A W653A W654A W655A W656A W657A W658A W670A W674A BLE A SIDE C7010 C7021 ...
Страница 400: ...RB1G CHASSIS W600A W603A W605A W607A W650A W651A W653A W654A W655A W656A W657A W658A W670A W674A BLX A SIDE R8627 C7021 ...
Страница 403: ...RB1G CHASSIS W600A W603A W605A W607A W650A W651A W653A W654A W655A W656A W657A W658A W670A W674A BLJ A SIDE C7010 ...