– 14 –
phones jack
set
32
Ω
level meter
(range: 0.5–5 V ac)
digital
voltmeter
100 k
Ω
TP (VT)
Put the lead-wire
antenna close to
the supplied MW/LW
loop antenna.
AM RF signal
generator
TP (FM ANT)
FM RF signal
generator
0.01
µ
F
set
FM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
87.6 MHz
108 MHz
Reading on Digital voltmeter
1.8
±
0.2 V
5.6
±
0.2V
Adjustment Part
L6
<confirmation>
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L5
CT1
87.6 MHz
108 MHz
AM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
530 kHz
1,710 kHz
(531 kHz)
(1,611 kHz)
Reading on Digital voltmeter
0.9
±
0.2 V
6.5
±
0.2V
(5.6
±
0.2V)
Adjustment Part
L2
CT2
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L9
CT4
620 kHz (621 kHz)
1,400 kHz (1,404 kHz)
( ) : Australian model.
Adjustment Location: See page 15.
TUNER SECTION 0 dB = 1
µ
V
• FM Section
Setting:
BAND switch: FM
22.5 kHz frequency
deviation by 400 Hz signal
output level : as low as possible
• AM Section
Setting:
BAND switch: AM
30% amplitude
modulation by
400 Hz signal
• Connecting Level Meter (FM and AM)
• Connecting Digital Voltmeter (FM and AM)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
Содержание PMC-107
Страница 4: ... 4 SECTION 1 GENERAL This section is extracted from instruction manual ...
Страница 5: ... 5 ...
Страница 6: ... 6 ...
Страница 7: ... 7 ...
Страница 12: ... 12 1 BVTP 3x8 2 BVTP 3x8 4 CONTROL board 3 CNP803 2 8 CONTROL BOARD ...
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......