![Sony NXL-IP55 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/sony/nxl-ip55/nxl-ip55_operation-manual_417410026.webp)
Menus
26
2. Reference in
Status
Displays the status of the synchronization signal.
No Detection:
The synchronization signal cannot be detected.
Locked:
Synchronized with specified synchronization signal.
Unlocked:
Not synchronized with specified synchronization signal.
N
Source
Selects the signal to be used as the synchronization signal.
Reference in:
Input signal from the REF IN connector.
SDI in 1:
Input signal from HD SDI IN connector 1.
Y
Format
Selects the format of the synchronization signal.
HD:
HD (3-value sync)
SD:
SD (sync or BB)
Y
V Phase
Specifies the vertical phase of this unit for the input synchronization signal.
–562 to 0 to +562
(for 1080 59.94i/50i)
–375 to 0 to +375
(for 720 59.94P/50P)
Y
3. Reference out
Format
Selects the format of the synchronization signal output from the REF OUT
connector.
HD:
HD (3-value sync)
SD (BB):
SD (BB)
SD (SYNC):
SD (sync)
Y
V Phase
Specifies the vertical phase of this unit for the output synchronization signal.
–562 to 0 to +562
(for 1080 59.94i/50i)
–375 to 0 to +375
(for 720 59.94P/50P)
Y
4. Embedded Audio Enable
SDI out 1
Embeds audio on HD SDI OUT connector 1. This is enabled under default
settings.
Y
SDI out 2
Embeds audio on HD SDI OUT connector 2. This is enabled under default
settings.
Y
SDI out 3
Embeds audio on HD SDI OUT connector 3. This is enabled under default
settings.
Y
SDI out 4
Embeds audio on HD SDI OUT connector 4. This is enabled under default
settings.
Y
Monitor out
Embeds audio on HD SDI OUT connector M. This is enabled under default
settings.
Y
5. Analog Audio Reference Level
Analog 1,2
Selects the reference level for the AUDIO/INTERCOM connector’s Analog 1 and
2 input/output.
–20 dBu
0 dBu
+4 dBu
Y
Analog 3,4
Selects the reference level for the AUDIO/INTERCOM connector’s Analog 3 and
4 input/output.
–20 dBu
0 dBu
+4 dBu
Y
Analog 5,6
Selects the reference level for the AUDIO/INTERCOM connector’s Analog 5 and
6 input/output.
–20 dBu
0 dBu
+4 dBu
Y
Item
Description