Assembly-28:
MB N Contact Unit holding position
MB N Contact Unit
Insert IS-075 Flexible Board into the connector on
IM Imager Unit 14M, then lock the connector.
Assemble Heat Sink and IM Imager Unit 14M.
Note: IS-075 Flexible Board can not be inserted after
assembling Heat Sink.
Heat Sink
IM Imager Unit 14M
IS-075 Flexible Board
Assembly-30:
Prior
Insertion of IS-075 Flexible Board
(NEX-3A/3D/3K)
Radiation Sheet (IS)
Heat Sink
Without running off the
edge of the hole.
Without running on the
edge of Heat Sink.
Assembly-31:
Radiation
Sheet (IS) putting position
SY-258 Complete Board
CN-439 Complete Board
Put the surplus part of the
shutter flexible board under
SY-258 Complete Board.
Assembly-32:
How to handle the Shutter Flexible Board
(NEX-3A/3D/3K)
Assembly-29:
Note when assembling Heat Sink
Align with the positioning hole.
Heat Sink
CN-439
Complete Board
LC Connector
Insulating Sheet
BT Frame Assy
Within 0.5mm
Within 0.5mm
Assembly-33:
LC Connector
Insulating Sheet
putting position
Assembly-34:
Tape AS (210) putting position
(NEX-5A/5D/5K/5CK/
5H
)
Tape AS (210)
Without protruding
from the rib top surface.
Without running off
the mask sheet.
Without running on this boss.
Assembly-35:
Method of attachment of LC Flexible
Insulating Sheet
(NEX-3A/3D/3K)
Bend the LC Flexible Insulating Sheet along
the curve of BT-063 Flexible Board.
LC Flexible
Insulating Sheet
±
1.0mm
The changed portions from
Ver.1.1 are shown in blue.
Ver.1.2 2010.07