12
MZ-NH700/NHF800
SECTION 4
TEST MODE
OUTLINE
A key having no particular description in the text, indicates a set
key.
1. ENTERING THE TEST MODE
Preparation:
Copy the “TestMode_Enter_For_900_800_700_600_600D_
Ver***.exe” folder of the PC application of the latest version to
your PC in advance. (operating system: Windows 2000, Windows
XP)
Also, when using this application, the SonicStage Ver. 2.0 or 2.1 is
necessary, and install it in your PC in advance.
Procedure:
1. If a Simple Burner has run on the PC, finish it (including the
one that is resident in the task tray).
2. Start the “TestMode_Enter_For_900_800_700_600_600D_
Ver***.exe”.
3. Insert the fully charged Ni-MH rechargeable battery (NH-
7WMAA).
4. Open and close the top panel of the main unit to wait until the
system reading finished.
5. Connect the main unit and PC by USB cable.
6. Check by device manager screen from property of “My
computer” that the set is recognised to your PC normally.
7. Click the
[Enter TestMode]
button on the screen of application
8. Disconnect the USB cable, when “OK” message is displayed
on the application screen.
9. Remove the battery.
Screen of the PC application “TestMode_Enter_For_900_800_
700_600_600D_Ver***.exe”
(“***” is version number)
Note:
Once the test mode is activated with this application, the test mode
is then activated forcibly by only turning on the power.
After the repair completed, be sure to release the test mode by using
this application once more.
2. OPERATION IN SETTING THE TEST MODE
•
When the test mode becomes active, first the Display Check
mode is selected.
•
Other mode can be selected from the Display Check mode.
•
When the test mode is set, the LCD repeats the following
display.
Display check mode:
“
00#
”: Model type 005 (MZ-NH700)
004 (MZ-NHF800)
“
*.***
”: Microcomputer version
•
When the
X
key is pressed and hold down, the display at that
time is held so that display can be checked.
3. RELEASING THE TEST MODE
Procedure:
1. If a Simple Burner has run on the PC, finish it (including the
one that is resident in the task tray).
2. Start the “TestMode_Enter_For_900_800_700_600_600D_
Ver***.exe”.
3. Insert the fully charged Ni-MH rechargeable battery (NH-
10WM).
4. Open and close the top panel of the main unit to wait until the
system reading finished.
5. Connect the main unit and PC by USB cable.
6. Check by device manager screen that the set is recognised to
your PC normally.
7. Click the
[Exit TestMode]
button on the screen of application
8. Disconnect the USB cable, when “OK” message is displayed
on the application screen.
9. Remove the battery.
Hi-MD
24
SYNC
All lit
All off
Microcomputer
version
display
Hi-SPLP
PCMMONO
1SHUFA-B PGM
REC
00#
Ver *.***
Ver 1.1