3. If NG in the overall CD adjustments, return to Reset NV and
perform from the electrical offset adjustment again.
LCD display
XXX: NG item No.
4. If OK through the overall CD adjustments, then perform overall
MO adjustments.
LCD display
5. Insert MO disc in the set, and press
> N
key to set the
Overall MO Adjustment mode. Automatic adjustments are made.
LCD display
XXX: Item No. for which an adjustment is being executed.
6. If NG in the overall MO adjustments, return to Reset NV and
perform the adjustment again.
LCD display
XXX: NG item No.
7. If OK through the overall MO adjustments, press
x
key to
return to the TEST MODE and terminate the Overall Adjustment
mode.
LCD display
5-5-3.Resume clear method
1. Setting the test mode.
2. Set the Manual mode and set the item No.043(RESUME Clear).
LCD display
3. Press the
X
key.
LCD display
5-5-4. Overall CD and MO adjustment items
1. Overall offset adjustment
000
XXX
NG
XXX
CD OK
XXX
MO RUN
000
MO OK
000
XXX
NG
043
Resume CC
043
Res ***
043
Res Clr
After reset is completed
LCD display
3. Overall MO adjustment items
Contents
GRV setting • Sarvo OFF • Head UP
Laser ON/OFF electrical offset difference
measurement
Item No.
030
035
Completed
2. Overall CD adjustment items
Contents
VC,VR power voltage High/Low selection
HPIT setting • Sarvo OFF
SLED move to inside
SLED move to outside
High reflection CD electrical offset adjustment
Laser ON • Focus UP • VC correction ALFA offset
adjustment
IJ offset adjustment
FE offset adjustment
HPIT adjustment
Focus servo ON
TE offset adjustment 1
TE gain adjustment
TWPP gain adjustment
TE offset adjustment 1
TE offset adjustment 2
Tracking servo ON
ABCD gain adjustment
KF gain correction
RF gain adjustment
FCS gain adjustment
TRK gain adjustment
Two-axis sensitivity adjustment (inside)
Two-axis sensitivity adjustment (outside)
Focus bias adjustment
HPIT setting • servo OFF
Item No.
761
300
561
562
312
313
314
320
324
321
328
324
332
330
336
337
338
344
345
521
522
341
300
Completed
Contents
VC,VR power voltage High/Low selection
R_GV setting
Low reflect MO offset adjustment
Laser ON • Focus UP • VC correction ALFA offset
adjustment
IJ offset adjustment
FE offset adjustment
Wpp denominator adjustment
LPIT adjustmet
LPIT setting • servo OFF
SLED move to inside
Focus servo ON
TE offset adjustment 1
TE gain adjustment
TE offset adjustment 1
TE offset adjustment 2
Item No.
761
100
112
113
114
118
200
561
220
224
221
224
232