SERVICE MODE
This set provides various modes for the service.
Enter the service mode through the procedure given below, and select the desired mode.
Procedure:
1. Press the
x
(CD),
x
(MD) and
[YES]
buttons at the same time.
2. Press the
[ AMS ]
(MD) knob and
x
(MD) button to display “ <To Normal> 0”.
3. At this time, turn the
[ AMS ]
(MD) knob can select all modes. For the contents of mode, see the following table.
4. To exit from the service mode, turn
[ AMS ]
(MD) knob to display “<To Normal> 0”, then press the
[ AMS ]
(MD)
knob.
Contents of test mode
l
L
No.
Display
Function
0
<To Normal> 0
Exit from test mode
1
<Version> 1
Microcomputer Version display
2
<FLD> 2
FL display test & LED display test
3
<Key, Jog> 3
Key/Jog input test
4
<CD Test> 4
CD all sorts test
5
0> COMMAND
Command transfer menu
6
1> ERROR
C1, C2 error display
7
2> SPEED X1
Disc speed selection
8
3> ISRC
ISRC display
9
4> CHECK8
Check 8 cm display
10
5> AUTO G
Auto gain display
11
6> HENSHIN
Decentiering display
12
7> PORT
Port selection
13
8> AMS ON
AMS display
14
9> TRK ON
TRK ON/OFF display
15
<MD Test> 5
MD all sorts test
16
<Retry & TOC> 6
MD TOC off & Retry test
17
<PC LINK> 7
PC connection check
18
<Initial> 8
All reset
19
<MD Update> 9
Software update
20
<Sircs> 10
Sircs code mode
21
<Dump> 11
Microcomputer Dump mode
22
<CD Aging> 12
CD aging
23
<Rep 5 off> 13
Cancel restriction of repeat five times
24
<KeyBoard> 14
Keyboard check
25
<Special> 15
Command, Sircs test
33
<CD ship> 16
Shipment mode
l
L
l
L
l
L