SMO-F551 / RMO-S551 Installation Guide
27
Installation Procedure on HP Systems
Test equipment:
The following procedure was confirmed with the following system and drive combination:
UNIX Workstation:
HP9000/712
OS:
HP-UX
A.09.07
Target: SMO-F551
Installation:
1) Connection
- Connect MO drive and UNIX Workstation using proper SCSI cable.
- Set proper SCSI ID on the MO drive. (In this case, SCSI ID = 4)
- Set proper termination.
Note
: The ‘ioscan’ command is useful to scan SCSI bus.
# ioscan -fc disk [enter]
2) Login
- Turn on the MO drive and the host computer, and insert a cartridge into the drive.
- Login as root.
- Confirm the connection of MO drive and UNIX Workstation using following command.
# diskinfo –v /dev /rdisk/c201d4s0 [Enter]
SCSI describe of /dev/rdsk/c201d4s0 *[4.1GB(4.8GB, 5.2GB)]
Vendor
:
SONY
product id
: SMO-F551
type
: optical memory
size
: 1986976 Kbytes (2319786, 2526944)
bytes per sector : 512(1024, 2048)
rev level
: 1.08
blocks per disk
: 3973952 (2319786, 1263472)
ISO version
: 0
ECMA version
: 0
ANSI version
: 2
removable media : yes
response format : 2
If the workstation return an error “diskinfo : can’t open /dev/rdsk/c201d1s0”, MO
drive is not connected with UNIX workstation correctly. You should shut down the
system and check the SCSI cable and SCSI terminator.