background image

8(GB)

MAIN MENU consists of the following menus.

1. HEADER DISPLAY
2. LOCATION DISPLAY
3. CUE DATA DISPLAY
4. SEARCH
5. REMOTE (Not available now)
6. SYSTEM MENU (Not available now)

Details for each menu are as follows.

HEADER DISPLAY menu

In this menu, it is possible to read the header data of a
memory label.

Note

With this menu, the only header information is read.

Displaying the HEADER DISPLAY menu

The “HEADER DISPLAY” menu is displayed with
either of the following procedures.

• In the <MAIN MENU>, move the cursor to

“HEADER DISPLAY” with turning the jog dial, and
click the jog dial or press the 

 key.

• In the <MAIN MENU>, press the numerical key “1.”

HEADER DISPLAY menu

ID (cassette ID) : 20 characters of ASCII
DBK (Data Base Key) : 20 characters of ASCII
TTL (TiTLe) : 24 characters of ASCII
ADM (ADMinistrator) : 

16 characters of ASCII

UPD (UPDated date) :

 yyyy(year)/mm(month)/

dd(data)

SNO (Serial NO.) : 7 digits
MDL (MoDeL name) : 12 characters of ASCII
THR (number of THReading) : 

0 to 32767

Reading the header data of a memory
label

1

Display the HEADER DISPLAY menu.

2

Position the data transfer area of the MLU-200
over a memory label.

3

Press the ACCESS key.

LOCATION DISPLAY menu

In this menu, it is possible to read the location data of a
memory label.

Displaying the LOCATION DISPLAY menu

The “LOCATION DISPLAY” menu is displayed with
either of the following procedures.

• In the <MAIN MENU>, move the cursor to

“LOCATION DISPLAY” with turning the jog dial,
and click the jog dial or press the 

 key.

• In the <MAIN MENU>, press the numerical key “2.”

LOCATION DISPLAY menu

ID:Cassette ID
DBK:Data base key
TTL:Title
ADM:Administrator
UPD:yyyy/mm/dd
SNO:1234567
MDL:Model name
THR:Thread

MAIN MENU

FLOOR NO.: 123
SHELF NO.: 785156
STEP NO.: 456
POSITION: 7890

Содержание MLU-200

Страница 1: ...注意事項を守らないと 火災 や人身事故になることがあります このオペレーションマニュアルには 事故を防ぐための重要な注意事項と製 品の取り扱いかたを示してあります このオペレーションマニュアルをよく お読みのうえ 製品を安全にお使いください お読みになったあとは いつ でも見られるところに必ず保管してください OPERATION MANUAL 1st Edition Revised 1 Serial No 10001 and Higher SYV Japanese English ...

Страница 2: ... received including interference that may cause undesired operation For the customers in Canada This device complies with RSS 210 of Industry Canada Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Pour les clients au Canada Cet apparei...

Страница 3: ...Denemarken Duitsland Groot Brittannië Finland Frankrijk Italië Nederland Noorwegen Oostenrijk Portugal Spanje Zweden en Zwitserland Sony erklærer herved at denne MLU 200 er i overensstemmelse med de grundlæggende krav og andre relevante bestemmelser i Direktiv 1995 5 EC Dette produkt er beregnet til anvendelse i følgende lande Østrig Danmark Finland Frankrig Tyskland Storbritannien Italien Holland...

Страница 4: ...ts 3 GB Front Panel 3 GB Rear panel 4 GB Connection 6 GB RS 232C Communication 6 GB Infrared data trafsfer 6 GB Start up 7 GB HEADER DISPLAY menu 8 GB MAIN MENU 8 GB LOCATION DISPLAY menu 8 GB CUE DATA DISPLAY menu 10 GB SEARCH menu 12 GB Specifications 13 GB English ...

Страница 5: ...n and long continuous operation Low power consumption is realized It is possible to operate for 8 hours or more continuously under the normal operation Mass data storage MLU 200 has a memory of 512K bytes Thanks to adoption of the memory stick2 mass data storage is realized Infrared communication Data can be transferred between MLU 200 and an external personal computer with infrared communication ...

Страница 6: ...when editing With turning this dial Selects the item Select the item to be edited when editing the data Move the cursor when editing the data With clicking this dial Fix the item to be selected Fix the item to be edited when editing the data Fix the contents to be edited when editing the data 3 IrDA Window for infrared transfers with a personal computer and an optional MLT 200 terminal 4F1 key Pre...

Страница 7: ... With pressing this key together with the CL key the edited data reverts Alphabetical and numerical keys A to Z 0 to 9 hyphen space and period Press these keys to input characters when editing data These keys are also pressed to select the menu to be displayed To select the menu press the numerical key of the menu number in MAIN MENU Return key Press this key to fix the selection of item The displ...

Страница 8: ...hese are charging terminals When a MLU 200 is put on a MLT 200 terminal with these terminals connected with ones of the MLT 200 charging starts When the battery voltage of the battery pack is 0 to charge the battery fully it takes approx 2 hours Note While charging the battery icon appears on the display When charging with an optional MLT 200 terminal be sure to put a MLU 200 on the MLT 200 secure...

Страница 9: ...6 GB RS 232C USB Communication Infrared communication Personal computer RS 232C cable or USB cable MLT 200 terminal To AC power supply AC adapter Personal computer with infrared Connection ...

Страница 10: ...is correct MAIN MENU Turning off MLU 200 To turn off a MLU 200 push the POWER button when the MAIN MENU is displayed Turning on MLU 200 with a battery pack already attached To turn on a MLU 200 push the POWER key MAIN MENU is displayed immediately MLU 200 Version x xx yy mm dd HH MM SS MAIN MENU HH MM 1 HEADER DISPLAY 2 LOCATION DISPLAY 3 CUE DATA DISPLAY 4 SEARCH 5 REMOTE 6 SYSTEM MENU Start up ...

Страница 11: ...haracters of ASCII ADM ADMinistrator 16 characters of ASCII UPD UPDated date yyyy year mm month dd data SNO Serial NO 7 digits MDL MoDeL name 12 characters of ASCII THR number of THReading 0 to 32767 Reading the header data of a memory label 1 Display the HEADER DISPLAY menu 2 Position the data transfer area of the MLU 200 over a memory label 3 Press the ACCESS key LOCATION DISPLAY menu In this me...

Страница 12: ... Editing the location data To edit the location data which is read in the LOCATION DISPLAY menu follow the procedure below 1 Press the BS key The cursor appears 2 Turn the jog dial to move the cursor to the item to be edited 3 Click the jog dial or press the key 4 Change the data To change the data Press the numerical keys To input the alphabet Press the SF key then press the alphabetical keys To ...

Страница 13: ... DATA DISPLAY with turning the jog dial and click the jog dial or press the key In the MAIN MENU press the numerical key 3 CUE DATA DISPLAY menu Scroll in the left direction Scroll in the left direction Scroll in the right direction Scroll in the right direction No SCN CUT TAK 000 A01 ABC1 001 001 A01 ABC1 002 002 A01 ABC1 003 nnn n01 zzz1 000 ST CUE POINT IN POINT NG 00 00 00 00 KP 00 01 53 12 OK...

Страница 14: ... the CUE DATA DISPLAY menu 2 Position the data transfer area of the MLU 200 over a memory label 3 Press the ACCESS key nnn comment scn CUE 00 00 00 00 cut IN taks OUT Editing the CUE data To edit the CUE data which is read in the CUE DATA DISPLAY menu follow the procedure below 1 Turn the jog dial to move the cursor to the CUE data to be edited in the CUE DATA DISPLAY menu 2 Click the jog dial or ...

Страница 15: ...ures In the MAIN MENU move the cursor to SEARCH with turning the jog dial and click the jog dial or press the key In the MAIN MENU press the numerical key 4 SEARCH START nn COUNT nn DATA abcdefghijklmn SEARCH menu START Number of the sector where the detection is started COUNT Number of sectors to be searched DATA Data to be searched Searching the data 1 Display the SEARCH menu 2 Turn the jog dial...

Страница 16: ...to 104 F External dimensions External dimensions Unit inch Supplied accessories Operation Manual 1 Shoulder strap 1 Optional accessories MSA 4A 8A 16A 32A Memory stick NP FS11 Rechargable battery pack Design and specifications are subject to change without notice Printed on recycled paper POWER ACCESS HANDY READER WRITER MLU 200 F1 F2 ABC CL BS SF 7 DEF 8 GHI 9 JKL 4 MNO 5 PQR 6 STU 1 VWX 2 YZ 3 0...

Страница 17: ......

Страница 18: ...t de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind und ausschließlich zum Gebrauch durch den Käufer der in dieser Anleitung beschriebenen Ausrüstung bestimmt sind Die Sony Corporation untersag...

Страница 19: ...Printed in Japan 2000 12 00 1999 MLU 200 J SYV 3 203 401 02 1 Sony Corporation Communication System Solutions Network Company ...

Отзывы: