— 31 —
SECTION 5
ELECTRICAL ADJUSTMENTS
5-1. PRECAUTIONS FOR CHECKING LASER DIODE
EMISSINON
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
5-2. PRECAUTIONS FOR USE OF OPTICAL PICK-
UP (KMS-260A)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when using it.
Before disconnecting the connector, desolder first. Before connect-
ing the connector, be careful not to remove the solder. Also take
adequate measures to prevent damage by static electricity. Handle
the flexible board with care as it breaks easily.
laser tap
flexible board
pick-up
Optical pick-up flexible board
5-3. PRECAUTIONS FOR ADJUSTMENTS
1) When replacing the following parts, perform the adjustments
and checks with
¬
in the order shown in the following table.
1. Temperature
compensation
offset adjustment
2. Laser power
adjustment
3. Traverse
adjustment
4. Focus bias
adjustment
Optical
Pick-up
BD Board
IC101, IC121, IC192
D101
IC171
¬
¬
¬
¬
¬
G
¬
¬
¬
¬
¬
G
G
G
G
¬
¬
¬
¬
¬
5. Error rate check
2) Set the test mode when performing adjustments.
After completing the adjustments, exit the test mode.
3) Perform the adjustments in the order shown.
4) Use the following tools and measuring devices.
• Check Disc (MD) TDYS-1
(Parts No. 4-963-646-01)
• Laser power meter LPM-8001 (Parts No. J-2501-046-A)
• Oscilloscope (Measure after performing CAL of prove.)
• Digital voltmeter
• Thermometer
• Jig for checking BD board waveform
(Parts No. : J-2501-124-A)
5) When observing several signals on the oscilloscope, etc.,
make sure that VC and ground do not connect inside the oscillo-
scope.
(VC and ground will become short-circuited.)
6) Using the above jig enables the waveform to be checked with-
out the need to solder.
(Refer to Servicing Note on page 5.)
5-4. CREATING CONTINUOUSLY RECORDED DISC
* This disc is used in focus bias adjustment and error rate check.
The following describes how to create a continuous recording
disc.
1. Insert a disc (blank disc) commercially available.
2. Rotate the AMS knob and display “CREC MODE”.
3. Press the YES button again to display “CREC MID”.
Display “CREC (0300)” and start to recording.
4. Complete recording within 5 minutes.
5. Press the NO button and stop recording .
6. Press the
§
button and remove the disc.
The above has been how to create a continuous recorded data for
the focus bias adjustment and error rate check.
Note :
• Be careful not to apply vibration during continuous recording.
Содержание MINIDISC DECK MDS-S38
Страница 8: ... 8 This section is extracted from instruction manual ...
Страница 9: ... 9 ...
Страница 10: ... 10 ...
Страница 11: ... 11 ...
Страница 12: ... 12 ...
Страница 13: ... 13 ...
Страница 14: ... 14 ...
Страница 15: ... 15 ...
Страница 16: ... 16 ...
Страница 17: ... 17 ...
Страница 18: ... 18 ...
Страница 19: ... 19 ...
Страница 20: ... 20 ...
Страница 21: ... 21 ...
Страница 26: ... 26 3 7 OVER WRITE HEAD 1 Precision screw P1 7x6 2 Over write head ...
Страница 38: ......
Страница 39: ......
Страница 40: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ......
Страница 67: ...MDS S38 MEMO 85 ...