MEX-BT3100P/BT3100U
6
EXTENSION CABLE AND SERVICE POSITION
When repairing or servicing this unit, connect the jig cable (extension cable (CD mecha)) as shown below.
• Connect the MAIN board (CN700) and the SERVO board (CN401) with the jig cable.
Jig cable:
Part No.
Description
A-1818-424-A
EXTENSION CABLE (CD MECHA)
SERVO board
(CN401)
MAIN board
(CN700)
extension cable (CD mecha)
CANCELLING THE DEMO MODE
You can cancel the demonstration display
which appears while this unit is turned off.
1
Press
, rotate the control dial
until “DISPLAY” appears, then press
it.
2
Rotate the control dial until “DEMO”
appears, then press it.
3
Rotate the control dial to select
“DEMO-OFF,” then press it.
The setting is complete.
4
Press
(BACK)
to
return to the
previous display.
The display returns to normal reception/
play mode.
MODEL IDENTIFICATION
– Bottom View –
Part No.
Model Number Label
Part No.
Destination
4-428-353-0
[]
BT3100P: US and Canadian models
4-428-358-0
[]
BT3100U: AEP and UK models
NOTE FOR REPLACEMENT OF THE USB CONNEC-
TOR (CN903) AND AUX JACK (J901)
To replace the USB connector and AUX jack requires alignment.
1. Insert the USB connector and AUX jack into the front panel.
2. Place the KEY board on the front panel and align the terminals
of the USB connector and AUX jack with the holes in the KEY
board.
3. Solder seven terminals of the connector and three terminals of
the jack.
KEY board
front panel
USB (socket) connector
(CN903)
AUX jack
(J901)