– 7 –
IOP DATA RECORDING AND DISPLAY WHEN OPTICAL PICK-UP AND NON-VOLATILE MEMORY (IC171
OF BD BOARD) ARE REPLACED
The IOP value labeled on the optical pick-up can be recorded in the non-volatile memory. By recording the value, it will eliminate the need
to look at the value on the label of the optical pick-up. When replacing the optical pick-up or non-volatile memory (IC171 of BD board),
record the IOP value on the optical pick-up according to the following procedure.
Record Precedure:
1. While pressing the
=
AMS
+
knob and
p
button, connect the power plug to the outlet, and release the
=
AMS
+
knob
and
p
button.
2. Turn the
=
AMS
+
knob to display “[Service]”, and press the
[YES]
button.
3. Turn the
=
AMS
+
knob to display “lop Write” (C28), and press the
[YES]
button.
4. The display becomes “Ref=@@@.@” (@ is an arbitrary number) and the numbers which can be changed will blink.
5. Input the IOP value written on the optical pick-up.
To select the number : Turn the
=
AMS
+
knob.
To select the digit
: Press the
=
AMS
+
knob.
6. When the
[YES]
button is pressed, the display becomes “Measu=@@@.@” (@ is an arbitrary number).
7. As the adjustment results are recorded for the 6 value. Leave it as it is and press the
[YES]
button.
8. “Complete!” will be displayed momentarily. The value will be recorded in the non-volatile memory and the display will become “Iop
Write”.
9. Press the
[REPEAT]
button to complete.
Display Precedure:
1. While pressing the
=
AMS
+
knob and
p
button, connect the power plug to the outlet, and release the
=
AMS
+
knob
and
p
button.
2. Turn th
=
AMS
+
knob to display “[Service]”, and press the
[YES]
button.
3. Turn the
=
AMS
+
knob to display “lop Read” (C27).
4. “@@.@/##.#” is displayed and the recorded contents are displayed.
@@.@ : indicates the IOP value labeled on the optical pick-up.
##.#
: indicates the IOP value after adjustment
5. To end, press the
=
AMS
+
knod or
[MENU/NO]
button to display “Iop Read”. Then press the
[REPEAT]
button.