– 28 –
5-5.
TEMPERATURE COMPENSATION OFFSET
ADJUSTMENT
Save the temperature data at that time in the non-volatile memory
as 25 °C reference data.
Notes:
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 °C to
28 °C. Perform it immediately after the power is turned on
when the internal temperature of the unit is the same as the
ambient temperature of 22 °C to 28 °C.
3. When D101 has been replaced, perform this adjustment after
the temperature of this part has become the ambient tempera-
ture.
Adjusting Method:
1. Turning the SELECTOR knob and display “TEMP AD-
JUST”.
2. Press the ENTER/YES button and select the “TEMP AD-
JUST” mode.
3. “TEMP =
” and the current temperature a data will be dis-
played.
4. To save the data, press the ENTER/YES button.
When not saving the data, press the EDIT/NO button.
5. When the ENTER/YES button is pressed, “TEMP=
SAVE” will be displayed for some time, followed by “TEMP
ADJUST”.
When the EDIT/NO button is pressed, “TEMP ADJUST”
will be displayed immediately.
Specifications:
The temperature should be within “E0-EF”, “F0-FF”, “00-0F”,
“10-1F” and “20-2F”.
+
–
BD board
digital voltmeter
CN110 pin
5
(I+3 V)
CN110 pin
4
(IOP)
Optical pick-up
objective lens
laser
power meter
5-6.
LASER POWER ADJUSTMENT
Connection:
Adjusting Method:
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the
0
button
or
)
button and move the optical pick-up.)
Connect the digital voltmeter to CN110 pin
5
(I+3 V) and
CN110 pin
4
(IOP) of the BD board.
2. Turning the SELECTOR knob and display “LDPWR AD-
JUST”.
(Laser power: for adjustment)
3. Press the ENTER/YES button and display “LD 0.9 mW $
”.
4. Turning the SELECTOR knob so that the reading of the la-
ser power meter becomes 0.82 to 0.91 mW.
Set the range control on the laser power meter to 10 mW, then
press the ENTER/YES button to save the adjustment result
in the non- volatile memory.
(“LD SAVE $
” will be displayed for a moment.)
5. Then “LD 7.0 mW $
”will be displayed.
6. Turning the SELECTOR knob so that the reading of
the laser power meter becomes 6.9 to 7.1 mW, press the
ENTER/YES button and save the adjustment result in the non-
volatile memory.
(“LD SAVE $
” will be displayed for a moment.)
Note: Do not perform the emission with 7.0 mW more than 15
seconds continuously.
7. Turning the SELECTOR knob and display “LDPWR
CHECK”.
8. Press the ENTER/YES button and display “LD 0.9 mW $
”.
Check that the reading of the laser power meter becomes 0.80
to 0.96 mW.
9. Press the ENTER/YES button and display “LD 7.0 mW $
”.
Check that the reading of the laser power meter and digital
voltmeter satisfy the specified value.
Specification:
Laser power meter reading : 7.0 ± 0.2 mW
Digital voltmeter reading
: Optical pick-up displayed value ±10%
10. Press the EDIT/NO button and display “LDPWR CHECK”,
and stop the laser emission.
(The EDIT/NO button is effective at all times to stop the la-
ser emission.)
KMS260A
27X40
B0825
lOP=82.5 mA in this case
lOP (mA) = Digital voltmeter reading (mV)/1 (
Ω
)
(Optical pick-up label)
Содержание MDS-EX77
Страница 7: ... 7 SECTION 2 GENERAL This section is extracted from instruction manual ...
Страница 8: ... 8 ...
Страница 9: ... 9 ...
Страница 10: ... 10 ...
Страница 11: ... 11 ...
Страница 12: ... 12 ...
Страница 13: ... 13 ...
Страница 14: ... 14 ...
Страница 15: ... 15 ...
Страница 16: ... 16 ...
Страница 17: ... 17 ...
Страница 18: ... 18 ...
Страница 34: ... 37 ...
Страница 35: ... 38 ...
Страница 36: ... 39 ...
Страница 37: ... 40 ...
Страница 38: ... 41 ...
Страница 39: ... 42 ...
Страница 40: ... 43 ...
Страница 41: ... 44 ...
Страница 42: ... 45 ...
Страница 43: ... 46 ...
Страница 44: ... 47 ...
Страница 45: ... 48 ...
Страница 46: ... 49 ...
Страница 47: ... 50 ...
Страница 48: ... 51 52 6 6 PRINTED WIRING BOARDS MAIN DISPLAY Section See page 32 for Circuit Boards Location ...