![Sony MB-806A Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/sony/mb-806a/mb-806a_service-manual_415884037.webp)
3-11
MB-806A (CE)
WRU-806A (CE, AU)
3. Frequency characteristic check
Procedure
Step 1:
Tuner
[1]
(Tuner unit 1) checking
n
The checking procedures describe that the WRU-806A (to be
adjusted) is installed into the Tuner
[1]
slot on the MB-806A.
(1) Set the MB-806A as follows;
Front panel (Tuner
[1]
)
Channel setting:
CE62 model; Group 00, 6301 channel (806.125 MHz)
CE69 model; Group 00, 6933 channel (858.125 MHz)
AU66 model; Group00, 6701 channel (799.250 MHz)
Muting: OFF
Rear panel
ATT (ANTENNA A, B) switch: 0 dB
(2) Connect the audio analyzer to the TUNER OUTPUT 1
connector via MIC amp.
(3) Connect the signal generator to the ANTENNA A IN
connector with DC cut fixture.
(4) Set the signal generator as follows:
Signal generator setting
FREQUENCY(carrier frequency):
CE62 model; 806.125 MHz
CE69 model; 858.125 MHz
AU66 model; 799.250 MHz
RF OUTPUT (Output level): 60 dB
u
V
EMF
(=
_
53 dBm)
MODULATION (Modulation frequency): 1 kHz
DEVIATION (Frequency deviation):
±
12 kHz
(5) Read the output level of the TUNER OUTPUT 1
(indication of the audio analyzer).
This level is specified to be 0 dB.
(6) Change the MODULATION (modulation frequency)
of the signal generator as follows, and check the output
level with respect to the output level under the proce-
dure (3) is set also as follows.
n
100 Hz and 15 kHz modulation frequency must be set
by using the function generator.
MODULATION frequency
TUNER OUTPUT 1 connector
of signal generator
output level
100 Hz
_
0.7
±
1.0 dB
15 kHz
_
28.5
±
2.5 dB
(7) Connect the signal generator to the ANTENNA B IN
connector with DC cut fixture, and perform the
procedures (4), (5) and (6).
Step 2:
Tuner
[2]
to Tuner
[6]
checking
When the WRU-806A Tuner Unit is installed in the Tuner
[2]
(Tuner unit 2) to Tuner
[6]
(Tuner unit 6) of the MB-
806A, perform the adjustments from procedures (1) to (7)
of “Step 1. Tuner
[1]
(Tuner unit 1) checking” on the
respective tuner units that are installed in the MB-806A.
When performing the above described checking change the
following details as shown below, of the “Step 1. Tuner
[1]
(Tuner unit 1) checking”.
Tuner
[1]
→
Tuner
[2]
,
[3]
,
[4]
,
[5]
, and
[6]
TUNER OUTPUT 1
→
TUNER OUTPUT 2, 3, 4, 5, and 6
Содержание MB-806A
Страница 22: ......
Страница 26: ......
Страница 44: ......
Страница 68: ......
Страница 72: ...7 2 MB 806A CE WRU 806A CE AU 7 2 MB 871 MB 871 MB 871 A SIDE 1 674 361 11 ...
Страница 73: ...7 3 MB 806A CE WRU 806A CE AU 7 3 MB 871 MB 871 MB 871 B SIDE 1 674 361 11 ...
Страница 82: ......