11. Strobe White Balance Adjustment
Adjust the white balance when the strobe light flashes.
Subject
A plate which reflection rate is 18%
(1.0m from the front of the protection
glass)
Measurement Point
Display data of page : 1
Measuring Instrument
Adjustment remote commander
Adjustment Page
E
Adjustment Address
42, 43
Note 1:
Perform this adjustment in the dark room or use a dark box.
Note 2:
Any light other than the strobe light should not light up the plate.
Note 3:
Displayed data of page 1 of the adjustment remote commander.
1 :XX:XX
Strobe B data
Strobe R data
Switch setting:
1)
Flash emitter .................................................................. Open
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: E, address: 11, set data: 15, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 10, and set data: 58.
4)
Select page: 2, address: 56, and set data: 89.
5)
Select page: 2, address: 90, and set data: 00.
6)
Select page: 2, address: 91, and set data: 00.
7)
Select page: 2, address: 92, and set data: 00.
8)
Select page: 2, address: 93, and set data: 80.
9)
Select page: 2, address: 01, set data: 79, and press the PAUSE
button.
10) Select page: 2, address: 01, set data: 67, and press the PAUSE
button.
11) Check the flashing of the strobe light.
12) Select page: 0, address: 03, and set data: 05.
13) Select page: 1, and read the strobe R data and strobe B data.
14) Select page: E, address: 42, set the strobe R data, and press the
PAUSE button.
15) Select page: E, address: 43, set the strobe B data, and press the
PAUSE button.
Processing after Completing Adjustments
1)
Select page: E, address: 11, set data: 18, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 0, address: 03, and set data: 00.
4)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
5)
Select page: 2, address: 10, and set data: 00.
6)
Select page: 2, address: 56, and set data: 00.
7)
Select page: 2, address: 90, and set data: 00.
8)
Select page: 2, address: 91, and set data: 00.
9)
Select page: 2, address: 92, and set data: 00.
10) Select page: 2, address: 93, and set data: 00.
12. Strobe Light Level and White Balance Check
Check the light level regulation and the white balance when the
strobe light flashes.
Subject
A plate which reflection rate is 18%
(1.0m from the front of the protection
glass)
Measurement Point
Display data of page : 1
Measuring Instrument
Adjustment remote commander
Specified Value
Y level data : 70 to 95 (Note 3)
R-Y data : FA to FF or 00 to 06 (Note 4)
B-Y data : FA to FF or 00 to 06 (Note 4)
Note 1:
Perform this adjustment in the dark room or use a dark box.
Note 2:
Any light other than the strobe light should not light up the plate.
Note 3:
Display data of page 1 of the adjustment remote commander.
1 :00:XX
Y level data
Note 4:
Display data of page 1 of the adjustment remote commander.
1 :XX:XX
B-Y data
R-Y data
Switch setting:
1)
Flash emitter .................................................................. Open
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: E, address: 11, set data: 15, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 10, and set data: 58.
4)
Select page: 2, address: 56, and set data: 89.
5)
Select page: 2, address: 90, and set data: 00.
6)
Select page: 2, address: 91, and set data: 00.
7)
Select page: 2, address: 92, and set data: 00.
8)
Select page: 2, address: 93, and set data: 80.
9)
Select page: 2, address: 01, set data: 79, and press the PAUSE
button.
10) Select page: 2, address: 01, set data: 67, and press the PAUSE
button.
11) Check the flashing of the strobe light.
12) Select page: 0, address: 03, and set data: 01.
13) Select page: 1, and check that the Y level data satisfies the
specified value. (Note 3).
14) Select page: 0, address: 03, and set data: 04.
15) Select page: 1, and check that the R-Y data satisfies the specified
value and the B-Y data satisfies the specified value. (Note 4)
Processing after Completing Adjustments
1)
Select page: E, address: 11, set data: 18, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 0, address: 03, and set data: 00.
4)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
5)
Select page: 2, address: 10, and set data: 00.
6)
Select page: 2, address: 56, and set data: 00.
7)
Select page: 2, address: 90, and set data: 00.
8)
Select page: 2, address: 91, and set data: 00.
9)
Select page: 2, address: 92, and set data: 00.
10) Select page: 2, address: 93, and set data: 00.
Содержание Mavica MVC-FD91
Страница 8: ...1 1 MVC FD91 SECTION 1 GENERAL This section is extracted from instruction manual ...
Страница 9: ...1 2 ...
Страница 10: ...1 3 ...
Страница 11: ...1 4 ...
Страница 12: ...1 5 ...
Страница 13: ...1 6 ...
Страница 14: ...1 7 ...
Страница 15: ...1 8 ...
Страница 16: ...1 9 ...
Страница 17: ...1 10 ...
Страница 18: ...1 11E ...
Страница 27: ...MVC FD91 SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM 3 1 3 2 3 3 MVC FD91 ...
Страница 32: ...MVC FD91 3 6 POWER BLOCK DIAGRAM 3 18 3 19 3 20E IC301 0 8Vp p 2 2µsec IC301 2 0Vp p 2 1µsec ...
Страница 36: ...MVC FD91 4 12 4 13 4 14 STEADY SHOT CONTROL VP 49 VP 49 BOARD 1 IC237 2 8Vp p 12MHz ...
Страница 58: ...MVC FD91 MF ZM SW BLOCK MVC FD91 4 82E ...