2-14 (E)
MAV-555
2-3-5. FP-115 Board
Side A (Component side)
Switches
Ref. No. Address
Name
Function
Factory setting
S201
(C-3)
Reset switch
Initializes the hardware.
–––
S207
(F-3)
Mode selector
Sets the mode.
switch
S207-1 :
For testing software
S207-2 :
For testing software
S207-3 :
For testing software
S207-4 :
For testing software
S207-5 :
For FL tube test
S207-6 :
For FL tube test
S207-7 :
For FL tube test
S207-8 :
For FL tube test
LEDs
Ref. No.
Address
Color
Function
Normal condition
D101
(G-3)
Green
Flashes approximately every 1.5 seconds
Flashes
when the circuit board is operating normally.
D102
(G-3)
Green
Flashes when the command is sent to
Flashes
the EM board.
D103
(G-3)
Green
Flashes when data is written to the FL tube.
Flashes
D104
(G-3)
Red
Lights up when an error occurs.
Lights off
1
2
3
A
B
C
D
E
F
G
D104
D103
D102
D101
S201
S207
2-3. Description of Internal Switches and Indicators
ON
1
2
3 4
5 6 7 8