– 48 –
KV-HR32K90/HR32M31
RM-1012
RM-1007
4-3. CONVERGENCE ADJUSTMENT
Preparation :
•
Before starting this adjustment, adjust the focus, horizontal
size and vertical size.
•
Set the Picture Mode to “STANDARD”.
•
Cross hatch / Dot pattern.
4-3-1. Horizontal and Vertical Static Convergence
1. (Moving horizontally), adjust the H.STAT control so that the
red, green and blue dots are on top of each other at the center
of the screen.
2. (Moving vertically), adjust the V.STAT magnet so that the
red, green and blue dots are on top of each other at the center
of the screen.
3. If the H.STAT variable resistor cannot bring the red, green
and blue dots together at the center of the screen, adjust the
horizontal convergence with the H.STAT variable resistor and
the V.STAT magnet in the manner given below.
(In this case, the H.STAT variable resistor and the V.STAT
magnet influence each other, so be sure to perform adjust-
ments while tracking.)
Fig. 4-3
Red
Blue
Green
Fig. 4-4
Purity control
corrects this area.
Deflection yoke positioning
corrects these areas.
Fig. 4-2
Center dot
R G B
R
G
B
H. STAT VR
V. STAT
Magnet
RV9001
H. STAT
C Board
Содержание KV-HR32K90
Страница 69: ... 76 KV HR32K90 HR32M31 RM 1012 RM 1007 MEMO ...
Страница 104: ...KV HR32K90 HR32M31 RM 1012 RM 1007 146 145 SF LANDING SF BOARD A Side SF BOARD B Side ...
Страница 105: ...KV HR32K90 HR32M31 RM 1012 RM 1007 147 148 T TELE TEXT T BOARD A Side T BOARD B Side ...
Страница 107: ...KV HR32K90 HR32M31 RM 1012 RM 1007 151 152 2 3 4 5 6 7 8 A 1 B C D E F G UG BOARD B Side ...
Страница 108: ... 153 KV HR32K90 HR32M31 RM 1012 RM 1007 W VM W BOARD ...
Страница 153: ... 198 KV HR32K90 HR32M31 RM 1012 RM 1007 9 965 399 01 Sony EMCS Corporation Ichinomiya TEC English 2004AR02 1 2004 1 ...
Страница 260: ...107 Additional Information ...