– 14 –
KV-AR252M61
RM-W102
e. OTHER FUNCTION VIA REMOTE COMMANDER
7
,
-
All the data becomes the values in memory.
8
,
-
All user control goes to the standard state.
[Display]
,
-
Service data initialization (Be sure not to use usually.)
2
,
5
Select Device or Category (Up, Down)
3-2. ADJUSTMENT METHOD
Item Number 000 HPOS
This explanation uses H POSITION as an example.
1. Select "000 HPOS" with the
1
and
4
buttons, or
2
and
5
.
2. Raise/lower the data with the
3
and
6
buttons.
3. Select the optimum state. (The standard is IF for PAL reception.)
4. Write with the
[MUTING]
button. (The display changes to WRITE.)
5. Execute the writing with the
-
button. (The WRITE display will be changed to red color while excuting, and back to
SERVICE.)
Example on screen display :-
Use the same method for all Items. Use
1
and
4
to select the adjustment item, use
3
and
6
to adjust, write with
[MUTING]
, then execute the write with
-
.
Note
: 1. In
[WRITE]
, the data for all items are written into memory together.
2. For adjustment items that have different standard data between 50Hz or 60Hz, be sure to use the respective
input signal after adjustment.
1F
60
HPOS
GEOM
00
7F
0
000A
59
637S 1.0C
1F
WRITE
SERVICE
WRITE
60
HPOS
GEOM
00
7F
0
000A
59
637S 1.0C
1.0C
1F
60
HPOS
GEOM
00
7F
0
000A
59
637S
GREEN
Write with
[MUTING]
Write executed with
GREEN
RED
The WRITE display
then the display
returns to green
SERVICE.
Adjusted with
3
and
6
buttons.
Содержание KV-AR252M61 Trinitron
Страница 61: ... 72 KV AR252M61 RM W102 LA6510 10 1 IC ...