![Sony KV-21FS105 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/sony/kv-21fs105/kv-21fs105_service-manual_1330583023.webp)
23
KV-21FS105
KV-21FS105
5-1. CIRCUIT BOARDS LOCATION
CB Board
A Board
MB Board
5-2. PRINTED WIRING BOARDS AND
SCHEMATIC DIAGRAMS INFORMATION
All capacitors are in µF unless otherwise noted. pF : µµF 50V or less are
not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise specifi ed.
All resistors are in ohms. k
Ω
=1000
Ω
, M
Ω
=1000k
Ω
Indication of resistance, which does not have one for rating electrical
power, is as follows:
Pitch : 5mm
Rating electrical power :
1
/
4
W
1
/
4
W in resistance,
1
/
10
W and
1
/
8
W in chip resistance.
: nonfl ammable resistor
: fusible resistor
: internal component
: panel designation and adjustment for repair
: earth ground
: earth-chassis
All variable and adjustable resistors have characteristic curve B, unless
otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10M
Ω
digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production tolerances.
All voltages are in V.
S : Measurement impossibility.
SECTION 5: DIAGRAMS
REFERENCE INFORMATION
RESISTOR
: RN METAL FILM
: RC SOLID
: FPRD NONFLAMMABLE CARBON
: FUSE NONFLAMMABLE FUSIBLE
: RW NONFLAMMABLE WIREWOUND
: RS NONFLAMMABLE METAL OXIDE
: RB NONFLAMMABLE CEMENT
:
ADJUSTMENT RESISTOR
COIL
: LF-8L MICRO INDUCTOR
The components identifi ed by shading and
!
symbol are critical for safety.
Replace only with part number specifi ed.
The symbol
indicates a fast operating fuse and is displayed on the
component side of the board. Replace only with fuse of the same rating as
marked.
: B+line
: B-line (Actual measured value may be different).
: signal path (RF)
Circled numbers are waveform references.
The components identifi ed by
X
in this basic schematic diagram
have been carefully factory-selected for each set in order to satisfy
regulations regarding X-ray radiation. Should replacement be
necessary, replace only with the value originally used.
When replacing components identifi ed by
Y
, make the necessary
adjustments as indicated. If the results do not meet the specifi ed
value, change the component identifi ed by
X
and repeat the
adjustment until the specifi ed value is achieved.
(Refer to R562 adjustment on page 15.)
When replacing the parts listed in the table below, it is important to
perform the related adjustments.
Part Replaced ( )
Adjustment ( )
HV HOLD-DOWN
(R562)
B+ VOLTAGE
CONFIRMATION
DY, T505, CRT, IC1301, IC501, C507,
C520, C505, C509, C515, T504,
L508, C551, L510, C546, C537,
C547, D517, D518, D519, R560,
R561, R562, R563, R565, R566,
R567, R525........................A Board
IC601, PH601...................A Board
CAPACITOR
: TA TANTALUM
: PS STYROL
: PP POLYPROPYLENE
: PT MYLAR
: MPS METALIZED POLYESTER
: MPP METALIZED POLYPROPYLENE
: ALB BIPOLAR
: ALT HIGH TEMPERATURE
: ALR HIGH RIPPLE