SECTION 4
SAFETY RELATED ADJUSTMENT
When replacing the following components marked with
]
on the schematic diagram, always check hold-down volt-
age and if necessary re-adjust.
4-1. HV HOLD-DOWN ADJUSTMENT
1. Remove CN810. Connect HV meter to HV Block.
2. Connect External Power Supply to CN810
2
pin
(+135V) and
1
pin (GND).
Part Replaced (
]
)
E Board
C515,
C516,
C554,
D504,
D507,
L506,
Q502,
R1,
R514,
R516,
R517, T502,
T504 (FBT)
G Board IC6008
Part Replaced (
[
)
R1
3. Turn on the set.
4. Slowly up the supply voltage from 0V to 135V.
5. Receive dot picture and set PICTURE/BRIGHT-
NESS to minimum.
6. Slowly up the voltage until hold-down circuit works
(picture disappear).
7. Read the HV meter of peak HV voltage.
Spec: 34.5±0.75KV
8. If Hold-down voltage is less than 33.75KV then sol-
der R1=820K.
9. If hold-down voltage is over than 35.25KV then
take-off R514 and solder R1=9.1K.
+
–
2
CN810
Power
Supply
1
E BOARD
– CONDUCTOR SIDE –
CN810
CN505
CN505
R1
Fig. 4-1
Fig. 4-2
Fig. 4-3
Fig. 4-4
Remove the cap off
from the unused
terminal and connect a
static voltmeter there.
Содержание KP-EF41HK