– 46 –
KP-43T70/46C70/48S70/
48S72/53N74/53S70/61S70
RM-Y906
* In case of multiple error, last error is displayed.
[SENSOR POSITION]
• ERROR CODE SCREEN DISPLAY
* Error code will be displayed on center of screen for 3 seconds.
E 11 B
E 11 B
R. G. B
SENSOR NUMBER
ERROR CODE 10
ERROR
3
0
2
1
SCREEN
0 : UPPER SENSOR
1 : LEFT SENSOR
2 : RIGHT SENSOR
3 : LOWER SENSOR
• ERROR CODE DISPLAY IN REGI SERVICE MODE
PJE 2 9 1 4 0
ERR
ITEM NUMBER-29
ERROR CODE 40
SENSOR NUMBER
(ONLY "10"or "20")
R.G.B
G-0 (Blank)
R-1
B-2
3-11. AUTO REGISTRATION ERROR CODE LIST
00
No Error
10
Sensor Output Level Low
* Check wiring, beam position, sensor.
0 : Upper Center
1 : Middle Left
2 : Middle Right
3 : Lower Center
20
Sensor Output Level High
* Check OP-amp circuit.
0 : Upper Center
1 : Middle Left
2 : Middle Right
3 : Lower Center
30
Adjustment Loop Counter Overflow
* Check the data go far from the standard or not.
40
Regi Data Overflow
* Check the data go far from the standard or not.
50
Regi Data Overflow
* Check the data go far from the standard or not.
60
Offset Overflow
* Check the data go far from the standard or not.
70
Offset Overdrow
* Check the data go far from the standard or not.
ERROR
DISCRIPTION
NOTE
CODE
[ERROR CODE LIST]