CEF85B75C8FE03FE27E5B2DD5FD4FC586E1158C26A977376619C854F45DFDC1CD6D620D8336B9157
KLV-22/26/32/37BX200,205(CH)
8
SELF DIAGNOSIS FUNCTION
DIAGNOSTIC TEST INDICATORS
When an error occurs, the STANDBY LED will flash a set number
of times to indicate the possible cause of the problem.
If there is more than one error, the LED will identify the first of the
problem areas.
Result for all of the following diagnostic items are displayed on
screen.
If the screen displays a “0”, no error has occurred .
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY LED will automatically begin to flash.
The number of times the LED flashes translates to a probable source of the problem.
A definition of the STANDBY LED flash indicators is listed in the instruction manual for the user’s knowledge and reference.
If an error symptom cannot be reproduced, the remote commander can be used to review the failure occurrence data stored in memory to reveal past
problems and how often these problems occur.
STBY LED
Flash time
Service menu Item name
(Screeen Dsisplay)
Diagnostic Item Description
6
Inverter_ERR
When The connection to the Inverter board
is not proper, or the inverter board has
s om ething wrong.("Inverter_ERR")
8
AU PROT
When the connections of the s peaker has
DC level difference("AU PROT") Or Main
Am p has the Over Current or High
tem perature s tatus ("Am p_ERR").