- 31 -
MRX1
RM-Y1012
SECTION
3
ADJUSTMENTS
3
-1. VS, VD Voltage Adjustment
(PDM-4210/5010)
• Preparation for adjustment
1. Slide the DIP switch (S3201) No. 8 of P board to on
position with no silkscreen mark
r
.
2. Connect a digital voltmeter to the following terminals of
G board.
VS voltage=G board TP1701 (VS)-TP1502 (GND)
VD voltage=G board TP1501 (VD)-TP1502 (GND)
3. Connect a AC cord in DISPLAY UNIT.
4. Perform the adjustment in 10 seconds after connecting
the cord.
• Procedure for adjustment
1. Slide the DIP switch (S3201) No. 7 of P board to on
position with no silkscreen mark
r
.
2. Confirm the lighting of SONY LOGO LED.
3. Adjust the VS voltage to the following voltage value.
VS voltage of proper value for each model.
Ex.) VS proper value=185V thru 185.6V at 185V.
(Check the proper value with a seal on upper left of
panel unit. Refer to right Fig.)
4. Adjust the VD voltage to the following voltage value.
VD voltage ±0.3V of proper value for each model.
Ex.) VD proper value=64.7V thru 65.3V at 65.0V.
(Check the proper value with a seal on upper left of
panel unit. Refer to right Fig.)
5. Check a Fan rotation.
6. Slide the DIP Switch (S3201) No. 7 of P board to the off
position with the silkscreen mark
r
.
7. Slide the DIP Switch (S3201) No. 8 of P board to the off
position with the silkscreen mark
r
.
8. Disconnect an AC cord of DISPLAY UNIT.
9. Reconnect the AC cord in one second.
10. Assure that “POWER ON/STANDBY” LEDs is
flashing amber.
3
-2. White Balance Adjustment
(PDM-4210/5010)
• Measurement equipment
1. Color analyzer (CA-100 manufactured by MINOLTA)
2.
Signal generator (ASTRO DESIGN VG-828D)
• Measuring procedure
1. Dab the W/B adjustment jig (CA-100) at the glass face
of the panel.
2. Connect the Signal generator (VG-828D) to the DVI
terminal.
3. Input All-white signal and set the picture mode to
DYNAMIC.
4. Select”PNLCTRL” in the service mode menu and set “0
WBNO” at “0”
5. Select “SCNR” “SCNB” of “PDPWB” in the service
mode menu, and then adjust following W/B standardized
+6V
–0V
values of 6500K, 8000K, 9300K, 10000K and 13550K
to following values of X/Y.
6. After adjusting the values, at the values of the “SCNR”
or “SCNB” exceeding 128 (initialize value).
1) Reset a lager value of the “SCNR” or “SCNB” at 128.
2) Set the White Balances with the last of items and
“SCNG” to the X/Y values above.
7. After the above step, when these item are nonqualified
following conditions, set the largest one at 128 and
readjust the White Balance with the last two item.
1) No one of “SCNR”, “SCNB” and “SCNG” exceeding
128.
2) Confirm the item value 128 at least one item.
8. As a result above, input the sequential number of value
to the “SCNR”, “SCNB” and “SCNG”.
9. Repeat the same step 5 thru 8 for the W/B 1 thru 4 after
setting the “0 WBNO” at each W/B number.
10.Input following signals from the Signal generator (VG-
828D).
1) All-white signal (255/255) input
Y (luminance)=45cd/m
2
or more
2) 1/25Window (255/255) input
Y (luminance)=45cd/m
2
or more
W/B standardized values:
6500K+8MPCD
8000K+8MPCD
9300K+8MPCD
10000K
13550K
W/B
0
1
2
3
4
X
0.3133
±
0.003
0.2944
±
0.003
0.2838
±
0.003
0.2806
±
0.003
0.2684
±
0.003
Y
0.3297
±
0.003
0.3100
±
0.003
0.2981
±
0.003
0.2883
±
0.003
0.2700
±
0.003
W/B
X
Y
Содержание KE-P42MRX1
Страница 25: ... 25 MRX1 RM Y1012 2 1 3 4 5 2 2 MEDIA RECEIVER UNIT MBT MRX1 2 2 1 TOP COVER REMOVAL 1 2 2 2 U2 BOARD REMOVAL ...
Страница 26: ... 26 MRX1 RM Y1012 1 2 3 2 2 3 BASEPLATE AND HMP BOARD REMOVAL 4 1 2 3 5 2 2 4 H5 H6 AND H7 BOARD REMOVAL ...
Страница 27: ... 27 MRX1 RM Y1012 1 2 2 2 5 G BOARD REMOVAL ...
Страница 28: ... 28 MRX1 RM Y1012 2 3 1 5 4 6 8 7 2 2 6 A1 BOARD REMOVAL ...
Страница 29: ... 29 MRX1 RM Y1012 2 2 8 Service Connector for DIC Board 2 2 9 LVDS Service Cable 2 2 7 Service Position ...