30
KDF-42WE655/50WE655
KDF-42WE655/50WE655
2-5.
H/V CENTER CONFIRMATION AND ADJUSTMENTS
Please check the picture horizontal/vertical center after the replacement of the Optics Unit Block Assembly or any part of the Top assembly.
1. Check the H/V center with 480i monoscope signal in “Full” mode.
2. If the center is shifted, adjust using the following service items:
NOTE: Please record the steps shifted as
MDHP and
MDVP .
MDHP
MDVP
MID-X1 9 MDHP (for H center)
10 MDVP (for V center)
3. Change the WIDE mode to “Normal” and change the register data as follows:
MID-X1fififi9fiffififififiM
(Don'tfichangefithefiMDVPfidat
4. Display the Twin Picture with the “split” button of the remote commander and change the registers data as follows:
fiMID-X1fififi9fiffififififiM
fi10fiffififififiM
5. Press “Favorites” button and change the registers data as follows:
MID-X1 9 MDHP + MDHP
10 MDVP + MDVP
6. OSD horizontal position must be adjusted as follows:
If above sum exceeds 255, set 1 to “16 RP1H” and set the “sum-256” to “17 RP1L”.
Since the registers are different from other cases, be careful to follow complete instructions, and write the data before changing the display/