34
KD-32FS130/36FS130
KD-32FS130/36FS130
4-1. REMOTE ADJUSTMENT BUTTONS AND
INDICATORS
SECTION 4: CIRCUIT ADJUSTMENTS
Electrical Adjustments by Remote Commander
Use the Remote Commander
(RM-YD001)
to
perform the circuit adjustments in this section.
Test Equipment Required:
1. Pattern generator 2. Frequency counter 3. Digital multimeter 4. Audio oscillator
4-2. ACCESSING THE SERVICE
ADJUSTMENT MODE
1. Standby mode (Power off).
2. Press the following buttons on the remote commander within a
second of each other:
DISPLAY
Channel 5
Sound Volume +
POWER
The screen displays the fi rst service data category item.
Category
Display
Item
Display
Data
Signal
Type
Channel
Type
NTSC
VIDEO1
DEF
M6J586MK-050FP
F1.2
HSIZ
1:35 NVM:OK
1. On the Remote Commander press 2 or 5 to select the category.
2. Press 1 or 4 to select the item.
3. Press 3 or 6 to change the data value.
4. Press MUTING then ENTER to write into memory.
Category
Display
Item
Display
Data
Signal
Type
Channel
Type
NTSC
WRITE
DEF
M6J586MK-050FP
F1.2
HSIZ
1:35 NVM:OK
Text
changes to
“WRITE” and
changes
colors from
green to red
MUTING
(Enter into
memory)
8
(Initialize)
5
Display previous
Category
3
Increase
Data value
0
(Remove from
memory)
ENTER
(Enter into
memory)
6
Decrease
Data value
1
Display next
Item
2
Display next
Category
4
Display previous
Item
DISPLAY
(Service Mode)
POWER
(Service Mode)
VOLUME (+)
(Service Mode)
RM-YD001
Содержание KD-36FS130 - 36" Fd Trinitron Wega
Страница 39: ...KD 32FS130 36FS130 KD 32FS130 36FS130 39 4 6 SERVICE DATA LISTS ...
Страница 40: ...KD 32FS130 36FS130 KD 32FS130 36FS130 40 ...
Страница 41: ...KD 32FS130 36FS130 KD 32FS130 36FS130 41 ...
Страница 42: ...KD 32FS130 36FS130 KD 32FS130 36FS130 42 ...
Страница 43: ...KD 32FS130 36FS130 KD 32FS130 36FS130 43 ...
Страница 44: ...KD 32FS130 36FS130 KD 32FS130 36FS130 44 ...
Страница 45: ...KD 32FS130 36FS130 KD 32FS130 36FS130 45 ...
Страница 46: ...KD 32FS130 36FS130 KD 32FS130 36FS130 46 ...