background image

— 2 —

SAFETY  CHECK-OUT

After correcting the original service problem, perform the follow-
ing safety checks before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
described below.

LEAKAGE

The AC leakage from any exposed metal part to earth Ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microampers). Leak-
age current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA

WT-540A. Follow the manufacturers’ instructions to use these
instruments.

2. A battery-operated AC milliammeter. The Data Precision 245

digital multimeter is suitable for this job.

3. Measuring the voltage drop across a resistor by means of a VOM

or battery-operated AC voltmeter. The “limit” indication is 0.75
V, so analog meters must have an accurate low-voltage scale.
The Simpson 250 and Sanwa SH-63Trd are examples of a pas-
sive VOM that is suitable. Nearly all battery operated digital
multimeters that have a 2V AC range are suitable. (See Fig. A)

Fig. A. Using an AC voltmeter to check AC leakage.

To Exposed Metal
Parts on Set

0.15

µ

F

1.5k

AC
voltmeter
(0.75V)

Earth Ground

ATTENTION AU COMPOSANT AYANT RAPPORT

 À LA SÉCURITÉ!!

LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 

!

 SUR

LES DIAGRAMMES SCHÉMATIQUES ET LA LISTE  DES

PIÈCES SONT CRITIQUES POUR LA SÉCURITÉ DE

FONCTIONNEMENT. NE REMPLACER CES COMPOSANTS

QUE PAR DES PIÈCES SONY DONT LES NUMÉROS

SONT DONNÉS DANS CE MANUEL OU DANS LES

SUPPLÉMENTS PUBLIÉS PAR SONY.

SAFETY-RELATED COMPONENT WARNING !!

COMPONENTS IDENTIFIED BY MARK 

!

 OR DOTTED LINE

WITH MARK 

!

 ON THE SCHEMATIC DIAGRAMS AND IN

THE PARTS LIST ARE CRITICAL TO SAFE OPERATION.

REPLACE THESE COMPONENTS WITH SONY PARTS

WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS

MANUAL OR IN SUPPLEMENTS PUBLISHED BY SONY.

Содержание IAD-IF70

Страница 1: ......

Страница 2: ...battery operated AC voltmeter The limit indication is 0 75 V so analog meters must have an accurate low voltage scale The Simpson 250 and Sanwa SH 63Trd are examples of a pas sive VOM that is suitable Nearly all battery operated digital multimeters that have a 2V AC range are suitable See Fig A Fig A Using an AC voltmeter to check AC leakage To Exposed Metal Parts on Set 0 15µF 1 5kΩ AC voltmeter ...

Страница 3: ... 3 SECTION 1 GENERAL This section is extracted from instruction manual ...

Страница 4: ... 4 SECTION 2 DISASSEMBLY 2 1 FRONT PANEL 1 Remove three screws and remove the case 3 Remove the claws 2 Screw BVTP 3X8 4 Front panel 3 Remove the claws 1 Knob 4 PANEL board 2 Two screws 2 2 PANEL BOARD ...

Страница 5: ......

Страница 6: ...our la sécurité Ne les remplacer que par une piéce portant le numéro spécifié 1 4 956 323 01 KNOB MIC 2 4 991 631 01 PLATE F INDICATION 3 4 991 632 01 PANEL FRONT 4 3 380 952 21 BUTTON 5 1 666 335 11 PANEL BOARD 6 1 558 945 21 CORD POWER POLAR SPT 1 US CND 6 1 575 651 21 CORD POWER AEP E 7 3 703 244 00 BUSHING 2104 CORD AEP E 7 3 703 571 00 BUSHING S 4516 CORD US CND Ref No Part No Description Rem...

Страница 7: ...list may be different from the parts specified in the diagrams or the components used on the set XX X mean standardized parts so they may have some difference from the original one Items marked are not stocked since they are seldom required for routine service Some delay should be anticipated when ordering these items RESISTORS All resistors are in ohms METAL Metal film resistor METAL OXIDE Metal ...

Отзывы: