HT-RT3
6
CAPACITOR ELECTRICAL DISCHARGE PROCESSING
When checking the board, for the electric shock prevention, con-
nect the resistors to both ends of respective capacitor (C201 and
C207) to discharge the capacitor (C201 and C207).
C207
C201
800
:
/2 W
800
:
/2 W
- REGULATOR, SWITCHING 3L405W-2 Board
(EXCEPT E12) (Conductor Side) -
- REGULATOR, SWITCHING 3L405W-3 Board
(E12) (Conductor Side) -
BOND FIXATION OF ELECTRIC PARTS
When REGULATOR, SWITCHING 3L405W-2 board (Except
E12), REGULATOR, SWITCHING 3L405W-3 board (E12) or
MAIN board is replaced, it is necessary to fi x parts to the boards
by using a specifi ed bond without fail.
• Object boards
1. REGULATOR, SWITCHING 3L405W-2 board (Except
E12)
2. REGULATOR, SWITCHING 3L405W-3 board (E12)
3.
MAIN
board
• Use bond
Part No.
Description
7-600-020-70
ADHESIVE (SC608Z2) 180ML
• Parts position
1. REGULATOR, SWITCHING 3L405W-2 board (Except
E12) (page 6)
2. REGULATOR, SWITCHING 3L405W-3 board (E12)
(page 6)
3. MAIN board (page 7)
1. REGULATOR, SWITCHING 3L405W-2 board (Except
E12)
C402
T201
C102
NR101
TH101 RC201
L101
L401 C461 C215 C204
C207
C211 T201
R208
C201
L102 C103
C101
*
The portion which applies bond:
– REGULATOR, SWITCHING 3L405W-2 Board
(EXCEPT E12) (Component Side) –
2. REGULATOR, SWITCHING 3L405W-3 board (E12)
C402
T201
C101
C102
C103
C204
C201
C207
C211
T201
R208
C215
C461
L401
L101
L102
NR101
RC201
TH101
*
The portion which applies bond:
– REGULATOR, SWITCHING 3L405W-3 Board
(E12) (Component Side) –