![Sony HKDV-900 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/sony/hkdv-900/hkdv-900_maintenance-manual_400650013.webp)
2-1 (E)
HKDV-900
Section 2
Troubleshooting
2-2. Self Diagnostic Mode
This unit allows executing the nine self diagnostic tests
below. (Refer to Section 2-2-3, “Starting and Quitting of
the Self Diagnostic Mode”.)
1. ROM version display
Displays the current ROM version on the 7SEG LED.
2. ROM test
Performs a ROM checksum test to check the memory
operation.
3. RAM test
Performs a RAM read/write test to check the memory
operation.
4. NV-RAM test
Performs an NV-RAM read/write test to check the
memory operation.
5. LED test
Checks that all the LEDs light.
6. 7SEG LED test
Performs a 7SEG LED light test to check the decoding
operation for numeric display.
7. Switch test
Checks the operation of a pushbutton switch.
8. Rotary encoder test
Checks the operation of a rotary encoder.
9. RS-422A test
Performs an RS-422A loop-back test to check the
communication operation.
2-1. Normal Diagnostic Function (Power
ON Test)
This unit executes the tests below automatically when
turning the power ON.
1. ROM (IC103 on the CP-364 board) test
(Error :
“
E0
”
)
This performs a ROM checksum test.
The “
E0
” display blinks on the 7SEG LED and the
operation stops when an error occurs. Replace the
ROM.
2. RAM (IC104 on the CP-364 board) test
(Error :
“
E1
”
)
This performs a RAM read/write test (in which cycle
data “
00
” through “
FF
”, “
FF
” and “
00
” are written
and read for comparison).
The “
E1
” display blinks on the 7SEG LED and the
operation stops when an error occurs. Replace the
RAM.
3. NV-RAM (IC201, 203 on the CP-364 board) test
(Error :
“
E2
”
)
This performs an NV-RAM read/write test (in which
data “
FF
” and “
00
” are written and read for compari-
son). But the data of the memory does not change.
The “
E2
” display blinks on the 7SEG LED and the
operation stops when an error occurs. Replace the
NV-RAM.
4. NV-RAM (IC201, 203 on the CP-364 board)
checksum test (Error :
“
E3
”
)
This performs an NV-RAM checksum test.
The “
E3
” display blinks on the 7SEG LED and the
operation stops when an error occurs. Replace the
NV-RAM.
5. Switch short test (Error :
“
EE
”
)
This test confirms that a switch is not short-circuited.
If the switch is short-circuited, the LED of the switch
blinks and the “
EE
” display blinks on the 7SEG LED
and the operation stops. Replace the short-circuited
switch.
Содержание HKDV-900
Страница 12: ......
Страница 50: ......
Страница 54: ......
Страница 72: ......
Страница 88: ...Printed in Japan Sony Corporation 2004 9 16 B P Company 2000 HKDV 900 SY J E 9 967 923 03 ...