![Sony Hi-MD Walkman MZ-RH10 Скачать руководство пользователя страница 72](http://html.mh-extra.com/html/sony/hi-md-walkman-mz-rh10/hi-md-walkman-mz-rh10_operating-instructions-manual_411934072.webp)
72
While recording
Symptom
Cause/Remedy
“NOT ENOUGH
POWER TO REC”
appears and recording
cannot be done on a
1GB Hi-MD disc.
• Recording is not possible when using a 1GB Hi-MD disc even when
the battery level indication shows enough power remaining while the
recorder is stopped or playing. This is because of a mechanism that
disables recording when the remaining battery power is estimated by
the recorder to be insufficient due to the high power consumption
required for 1GB Hi-MD disc recording.
,
Connect the AC power adaptor to the recorder or insert a fully
charged rechargeable battery or a new alkaline dry battery.
The remaining recording
time appears as “–00:00”
and recording cannot be
done, even though
2.0MB of free space is
displayed.
• This is a system limitation. 2.0MB is the capacity of the reserve
domain.
The recorder always
creates a new group
when recording.
• The group recording (“Group REC”) is set to “On”. (You cannot
overwrite tracks.)
,
Set the group recording setting to “Off” (page 37).
The first few seconds of
a track cannot be
recorded.
• If you start recording before the
x
indication appears in the display,
data will not be recorded to the first few seconds of the first track.
,
Wait until the
x
indication appears before you start recording.
Recording cannot be
done correctly.
• You tried to record in MD mode on this recorder.
,
Only Hi-MD mode can be used to record directly on this
recorder without using a computer. To record in MD mode,
connect the recorder to a computer and use the supplied software
(pages 22 and 30).
• Audio sources may not be securely connected.
,
Disconnect the audio sources once and connect them again
(pages 21 and 34).
• There is no digital signal from the portable CD player.
,
When recording digitally from a portable CD player, use the AC
power adaptor and disable the anti-skip function (such as ESP)
on the CD player.
• The analog recording was made using a connecting cord with an
attenuator.
,
Use a connecting cord without an attenuator.
• Recording level is too small to record (when adjusting the recording
level manually).
,
Pause the recorder and adjust the recording level (page 35).
• The recorder is connected to the computer.
,
Disconnect the recorder from the computer when recording.
• The power sources was disconnected or a power outage occurred
during recording.
,
The recording result is not recorded on the disc. Make recording
again.