19
MZ-NH1
3-7. Setting The Adjustment Values
3-7-1. Hi-MD3 setting
Preparation:
1. Perform calculation every item based on the data given by the
Hi-MD3 adjustment disc by referring to the following table.
(Round off the value in decimal place)
2. Convert the calculated value into hexadecimal number.
Note:
The Hi-MD3 adjustment parameters vary depending on the disc,
and therefore use the parameters of the disc used when performing
the adjustment.
Item No.
Calculating formula (
*
3)
0211
Pr_nominal / 0.05
(*1)
Por / 0.05
0212
Kr
×
(
−
100)
0213
Pw_nominal / 0.05
(*2)
Ppw / 0.05
0214
Kw
×
(
−
100)
0215
Prmin / 0.05
0216
Pwmin / 0.05
*1) If the “Pr_nominal” value is indicated, use the “Pr_nominal” value
and not used “Por” value.
*2) If the “Pw_nominal” value is indicated, use the “Pw_nominal” value
and not used “Ppw” value.
*3) Round off after the decimal point.
Table 3-7-1. Hi-MD3 adjustment parameter
Example of Calculation:
Item No.
Parameter
Result
Decimal
Hexadecimal
0211
Pr_nominal
2.50 mW
50
32h
0212
Kr
−
0.3 %/
°
C
30
1Eh
0213
Pw_nominal
7.35 mW
147
93h
0214
Kw
−
0.4 %/
°
C
40
28h
0215
Prmin
1.9 mW
38
26h
0216
Pwmin
5.8 mW
116
74h
Procedure:
1. In the test mode (Display Check mode), press the
[VOL+]
key
to enter the Manual mode.
2. Press the
[FF]
key once, press the
[VOL+]
key once, and press
the
[FF]
key once again to display as follows.
Display of the remote commander
3. Press the
[FF]
key once to select the item number 0211.
4. Adjust with
[VOL+]
/
[VOL--]
keys so that the adjustment value
of LCD becomes calculated value.
5. Press the
X
key to write the adjusted value.
6. Press the
[FF]
key to next item.
7. Repeat adjustment from step 4 until item number 0216.
3-7-2. Other setting
1. In the test mode (Display Check mode), press the
[VOL+]
key
to enter the Manual mode.
2. Press the
[FF]
key five time to select the item number 0113
and display as follows.
Display of the remote commander
3. Press the
[VOL+]
/
[VOL--]
key and set the according value to
each model type and destination referring to the following
table.
4. Press the
X
key to write the adjusted value.
Destination
Setting value
US, Australian
01
AEP, UK
81
E18, Hong Kong, Taiwan,
Korean, Chinese, Tourist
05
•
Abbreviation
E18: 100V - 240V AC area in E model
Table 3-7-2. Mode Type and Destination Setting
3-8. Servo Overall Adjustment
Note1:
Be sure to adjustment so that the set is horizontal and the LCD is
upside. Unless performed in that state, it is not adjusted correctly.
Note2:
If NG is displayed in the middle of this adjustments, perform “3-2.
Initialize The Adjustment Value” and “3-7. Setting The Adjustment
Values” again, then retry this adjustments from step 1.
Procedure:
1. Insert the full charged lithium-ion battery (LIP-4WM)
and enter the test mode (Display Check mode).
2. Press the
[VOL--]
key to enter the Overall Adjustment mode.
3. Insert the CD adjustment disc (TDYS-1).
4. Put the main unit horizontal so that the LCD becomes upside,
and press the
[FR]
key.
5. Wait until “CD OK” is displayed on the LCD.
6. Insert the MD1/HiMD1 hybrid adjustment disc
(MDW-74/GA1).
7. Put the main unit horizontal so that the LCD becomes upside,
and press the
[FF]
key.
8. Wait until “MD1 OK” is displayed on the LCD.
9. Insert the Hi-MD3 adjustment disc (HMD1GSDJ).
10. Put the main unit horizontal so that the LCD becomes upside,
and press the
[VOL+]
key.
11. Wait until “HMD OK” is displayed on the LCD.
12. Eject the disc.
13. Put the main unit horizontal so that the LCD becomes upside,
and press the
[VOL--]
key.
14. Wait until “OfstOK” is displayed on the LCD.
15. Press the
x
key and back to the Display Check mode.
2 1 0
P w r A d j
1 1 3
D i s t F * *
adjustment value (hexadecimal)