HCD-ZX66i/ZX99i
27
&&: Emerging error
01: Stop while chucking up.
02: Stop while chucking up.
03: Time-out of EX-CHANGE open.
05: Time-out of EX-CHANGE close.
##: Not used (value is fi xed to 00)
00: Not used (value is fi xed to 00)
• Display of BD errors. It is shown with “D” and 11 digits num-
ber.
D*$$%%&&##00
D*: The number of error history (“0” is latest one)
(Press [
>
] (CD) button to display next error)
$$: The detail of trouble
01: Focus error
02: GFS error
03: Setup error
%%: Not Used
&&: Processing operation when trouble occurs
00: No disc judgment without chucking retry.
01: No disc judgment after chucking retry.
##: The state when judged as no disc
01: Stop
02: Setup
03: TOC reading
04: Access
05: Playback
06: Pause
07: Manual search (Play)
08: Manual search (Pause)
00: Not used (value is fi xed to 00)
[CD REPEAT 5 LIMIT OFF MODE]
• The number of repeat for CD playback is 5 times when the re-
peat mode is “REPEAT ALL”. This mode enables CD to repeat
playback for limitless times.
Procedure:
1. Press
[
? / 1
] button to turn the set ON.
2. Select CD function.
3. Press [
M
] (iPod) button, [TUNING MODE] button and
[EX-CHANGE] button simultaneously to enter the CD repeat
5 limit off mode and the fl uorescent indicator tube displays
“LIMIT OFF”.
4. To release from this mode, operate the cold reset. (Refer to the
“MC COLD RESET”)
[CD SHIP MODE (WITH MEMORY CLEAR)]
• This mode moves the optical pick-up to the position durable to
vibration and clears all data including preset data stored in the
RAM to initial conditions. Use this mode when returning the
set to the customer after repair.
Procedure:
1. Press
[
? / 1
] button to turn the set ON.
2. Select CD function.
3. Press [EX-CHANGE] button and [
? / 1
] button simultane-
ously. The set will power off automatically.
4. After the “STANDBY” blinking display fi nishes, a message
“MECHA LOCK” is displayed on the fl uorescent indicator
tube and the CD ship mode is set.
5. Then AC power OFF.
[CD SHIP MODE (WITHOUT MEMORY CLEAR)]
• This mode moves the optical pick-up to the position durable
to vibration. Use this mode when returning the set to the cus-
tomer after repair.
Procedure:
1. Press
[
? / 1
] button to turn the set ON.
2. Select CD function.
3. Press [DISC SKIP] button and [
? / 1
] button simultaneously.
The set will power off automatically.
4. After the “STANDBY” blinking display fi nishes, a message
“MECHA LOCK” is displayed on the fl uorescent indicator
tube and the CD ship mode is set.
5. The AC power OFF.
[CD POWER MANAGE]
• This mode let you switch on or off power supply to the BU
during TUNER function.
• When CD POWER is set to OFF, the power supply to the BU is
cut off during TUNER function. It will increase the time taken
to access CD when function change from TUNER to CD but it
will improve tuner reception.
• When CD POWER is set to ON, the power supply to the BU
is not cut off during TUNER function. It will reduce the time
taken to access CD when function change from TUNER to CD
but it will decrease tuner reception performance.
Procedure:
1. Press
[
? / 1
] button to turn the set ON.
2. Select CD function.
3. Press
[
? / 1
] button to turn the set OFF.
4. When demonstration appear, press [
x
] (CD) button and
[
? / 1
] button simultaneously. The set will power on automati-
cally.
5. The message “CD POWER ON” or “CD POWER OFF” will
be displayed on the fl uorescent indicator tube.
[CD TRAY LOCK MODE]
• This mode let you lock the disc tray. When this mode is activat-
ed, the disc tray will not open when [OPEN/CLOSE] button or
[EX-CHANGE] button is pressed. The message “LOCKED”
will be displayed on the fl uorescent indicator tube.
Procedure:
1. Press
[
? / 1
] button to turn the set ON.
2. Select CD function.
3. Press and hold [
x
] (CD) button and [
Z
OPEN/CLOSE] but-
ton simultaneously until “LOCKED” or “UNLOCKED” dis-
played on the fl uorescent indicator tube (around 5 seconds).
[VACS DISPLAY]
• This mode is used to check the VACS level.
Procedure:
1. Press
[
? / 1
] button to turn on the system.
2. Press [
M
] (iPod) button, [TUNER MEMORY] button and
[DISC 3] button simultaneously.
3. During the VACS Level Display Mode, the fl uorescent indi-
cator tube displays “VACSx APy”. “x” represent VACS level
which is triggered by signal level, and “y” represent APVACS
(Abuse Protection VACS) level which is triggered.